5. Function Code Table
5-7
5.3. Parameter group (PAR_[][])
CODE
NO.
Comm.
Addr
CODE NAME
LCD
DISPLAY
SETTING DATA
Adjustment
During Run
RANGE
UNIT
DEFAULT
PAR_00
-
Jump for quick view Jump Code
1 ~ 38
-
-
Yes
PAR_01
7301 Initialize parameters
Para. init
0 (No)
1 (All Groups)
-
0 (No)
No
2 (DIS)
4 (PAR)
6 (CON)
8 (AIO)
10 (2ND)
12 (SYN)
14 (SLS)
3 (DIO)
5 (FUN)
7 (EXT)
9 (USR)
11 (E/L)
13 (WEB)
PAR_02
-
Read parameters
Para. read
0(No) / 1(Yes)
-
0 (No)
No
PAR_03
-
Write parameters
Para. write
0(No) / 1(Yes)
-
0 (No)
No
PAR_04
-
Parameter write
protection
Para. lock
0 ~ 255
-
0
Yes
PAR_05
-
Password
Password
0 ~ 9999
-
0
Yes
PAR_07
7307
Motor capacity
selection
Motor select
0 (2.2)
2 (5.5)
4 (11.0)
6 (18.5)
8 (30.0)
10 (45.0)
12 (75.0)
14 (110.0)
16 (160.0)
18 (280.0)
20 (375.0)
1 (3.7)
3 (7.5)
5 (15.0)
7 (22.0)
9 (37.0)
11 (55.0)
13 (90.0)
15 (132.0)
17 (220.0)
19 (315.0)
kW
-
No
21 (User Define)
1)
PAR_08
7308
Motor cap. selection
of USER
UserMotorSel
0.7 ~ 500.0
kW
5.5
No
PAR_09
7309 Motor cooling type
Cooling Mtd
0 (Self-cool)
1 (Forced-cool)
-
1
(Forced
cool)
Yes
PAR_10
730A
E
n
co
d
e
r
Pulse no.
Enc Pulse
360 ~ 4096
-
1024
No
PAR_11
730B
Direction
setting
Enc Dir Set
0 (A Phase Lead)
1 (B Phase Lead)
-
0
(A Phase
Lead)
No
PAR_12 730C
Error check
enabling
Enc Err Chk
0 (No) / 1 (Yes)
-
1 (Yes)
No
PAR_13 730D
LPF time
constant
Enc LPF
0 ~ 100
ms
1
Yes
PAR_14
730E
Error detection
time
EncFaultTime
0.00 ~ 10.00
sec
0.00
No
PAR_15
730F
Error reference
speed
EncFaultPerc
0.0 ~ 50.0
%
25.0
No