Appendix 1. Troubleshooting
App 1-19
Object
Error code
Occurren
ce
location
Error message
Reason and measure
Type
Address
Project
download
from USB
storage
device
0x27
0x57
XGT
Panel
Cannot read XGT
Panel software
version.
There is version information file but
when it can’t read file normally because
of the device error, downloading is
stopped because it doesn’t know
version. If this symptom is repeated,
contact Customer Service Center.
0x58
XGT
Panel
XGT Panel software is
old version. Please
update XGT Panel.
The version of XP-Builder where
project is saved is not compatible with
present XGT Panel. Update the XGT
Panel.
0x58
XGT
Panel
XP-Builder is old
version. Please
update XP-Builder.
The version of XP-Builder where
project is saved is not compatible with
present XGT Panel. Update the XGT
Panel.
0x59
XGT
Panel
Cannot read download
data format version.
There is storage structure version
information file. But when it can’t read
this file because of the device error,
downloading is stopped because it
doesn’t know the version. If this
symptom is repeated, contact
Customer Service Center.
0x5A
XGT
Panel
Download data format
version is not
matched. Please
update XGT Panel.
Data storage type is not correct.
Update XGT Panel.
0x5A
XGT
Panel
Download data format
version is not
matched. Please
update XP-Builder.
Data storage type is not correct.
Update the XP-Builder.
0x5B
XGT
Panel
Data file path is
invalid.
There is no project data file at
designated location. Check the
connection status of USB and if there is
no error, save the project to USB again.
0x5C
XGT
Panel
Download file name
length is invalid.
The name of project data file is not
saved correctly. Save the project at the
USB again. If this symptom is repeated,
contact Customer Service Center.
0x5D
XGT
Panel
Cannot find download
file.
The project data file can’t be found.
Save the project data file at the USB
again. When this symptom is repeated,
check the USB. If there is no error,
contact Customer Service Center.
Содержание iXP2 Series
Страница 72: ......
Страница 110: ......
Страница 111: ...Appendix2 Dimensions App 2 1 Appendix 2 Dimensions Unit mm 1 iXP2 08XX ...
Страница 112: ...Appendix 2 Dimensions App 2 2 2 iXP2 10XX ...
Страница 113: ...Appendix2 Dimensions App 2 3 3 iXP2 12XX ...
Страница 114: ...Appendix 2 Dimensions App 2 4 4 iXP2 15XX ...