ETHERNET, RJ45 Ethercon connector.
Two connectors are provided for TCP/IP, UDP, sACN, Art-Net and other network protocols.
The UHM can also be powered by connecting PoE to the top connector. See section 1.5.2.
The dual Ethernet connectors with an internal Ethernet switch allow the daisy-chaining of
multiple racks.
•
Touch Screen.
The home screen shows a real time display of RMS voltage and currents across all 3 phases
plus neutral within the rack. See section 2 for a full description of the Home screen.The touch
screen menu system is used for the internal configuration and for local control. See section 3
for full descriptions of the UNITOUR menu system.
1.5.2
Setup without 3 Phase Power
The UNITOUR rack can be quickly and easily pre-configured in the factory or warehouse
without the need for 3 phase power. It only requires a PoE Ethernet switch to connect to the
UHM control module which will power the UHM allowing the UNITOUR to be configured using
the touch screen
or via LSC’s HOUSTON X via a laptop or tablet.
Head Module Powered by PoE
1.5.3
Output Modules Overview
The UNITOUR can be supplied with two types of output module.
•
UDMT = Dimmer/Relay Switch module
•
USMT = Relay Switch module
The UNITOUR rack is supplied from the factory with either hard wired output modules or
Quick-Swap output modules.
The output module slot locations are labelled A to D (48 channels) or A to B (24 channel
models) from top to bottom of the rack.
The area below the channel circuit breakers is provided to write a descriptive label for each
output channel. It is Illuminated by dimmable LEDs. The intensity of the LEDs is controlled
from the “CONTROL” menu on the touch screen.
Ethernet Switch
providing PoE to
UNITOUR head module