XGT/XGB Series FEnet Driver
GP-Pro EX Device/PLC Connection Manual
13
Settings of External Device
Use the LS Industrial Systems setting tool (XG-PD Editor) to configure communication settings for the External
Device.
Refer to your External Device manual for details.
EtherNet module Setting
1
Start up the setting tool.
2
From the [File] menu, select [New File], and create the project.
3
From the [Online] menu, select [Connect].
4
From the [Online] menu, select [Read IO Information].
5
Double-click [FEnet] displayed in the tree view and set EtherNet module.
6
Select [Write Parameter(Standard Settings,HS Link,P2P)] from the [Online] menu after selecting [Connect] from
the [Online] menu and connecting External Device with communication setting software.
7
Select [Reset] from the [Online] menu, and reboot External Device.
Notes
•
Check with a network administrator about IP address.
Do not set the duplicate IP address.
Setup Items
Setup Description
IP Address
192.168.0.1
Subnet mask
255.255.255.0
Driver
XGT server