XGT/XGB Series FEnet Driver
GP-Pro EX Device/PLC Connection Manual
25
6
Device Code and Address Code
Use device code and address code when you select "Device Type & Address" for the address type in data displays.
6.1
XGK / XBM / XBC
Device
Device Name
Device Code
(HEX)
Address Code
Input / Output Relay
P
0080
Word Address
Auxiliary Relay
M
0082
Word Address
Keep Relay
K
0083
Word Address
Link Relay
L
0084
Word Address
Special Relay
F
0085
Word Address
*1
*1
Write disable
Timer (Current Value)
T
0060
Word Address
Counter (Current Value)
C
0061
Word Address
Data Register
D
0000
Word Address
Special Module Register
U
0002
Word Address
*2
*2
If the Word Address of Uxx.dd be specified indirectly, please calculate the following formula.
Word Address = [Convert 'xx' parts to the decimal value from the hexadecimal value] x 32 + [dd]
For example, 01.00 is 32, 10.00 is 512, 7F.00 is 4064.
Index Register
Z
0063
Word Address
Communication Data Register
N
0064
Word Address
File Register
R
0001
Word Address
File Register
ZR
0003
Word Address