XDesignerPlus Ver2.0 Communication Manual
10 / 13
■ [ Project >Project Property > Project >TOP Setting > TOP Name ]
Set communication interface of TOP.
-Right window : [HMI Setting > check HMI Setting using > Device manager].
-Right window : [HMI Setting > check HMI Setting using > PLC setting]
■ External device setup
Set the communication driver option “XGT(XGK), XGB(XBC,XBM) Series FENET”..
■ Setting communication Interface
item
Description
Serial Signal Level
Setup signal level(RS-232C/422/485) of PLC connected with COM2/1 port. (COM1 only RS-232C)
Serial Baud Rate
Setup [communications Baud rate] of PLC connected with COM2/1 port.
Serial Data Bit
Setup [Data Bit] of PLC connected with COM2/1 port.
Serial Stop Bit
Setup [Stop Bit] of PLC connected with COM2/1 port.
Serial Parity Bit
Setup [Parity Bit] of PLC connected with COM2/1 port.
Time Out [ x100 mSec ]
Setup [Time Out] of PLC connected with COM2/1 port. (Timeout:: waiting time for answer of PLC)
Send Wait [ x10 mSec ]
Setup [Send Wait] of PLC connected with COM2/1 port.
(Send Wait: communicate after waiting setting time when touch screen requires communications.)
Station Num. in Diag.[0~31]
Setup [Station Num.(0~31)] using "4.3 Communication Diagnosis”
4. Communication setting
Communication setup can be set on XDesignerPlus or TOP Main Menu. The setting should be the same with the external device.
(1) XDesignerPlus setup – register information of external device