Chapter 7 Exclusive Functions for iS7 Inverter Control/Monitoring
7-2
Symbol
Name
Description
J3
NPN/PNP Selection
Jumper
1) NPN mode: connects terminal block input (P00~P05) and 24G.
for details, see page 7-5.
2) PNP mode: connects terminal block input (P00~P05) and 24P.
for details, see page 7-5.
CON1
RS232C
Communication
Connector
Connector for connection with KGLWIN
Battery
Battery Housing
1) Function: in case of power failure, maintain the data of the latch
area of PLC option and RTC time data.
2) Battery type: coin-type lithium ion battery (CR2032)
3) Service life: approx. 4 years in power-off state (at room
temperature, battery capacity 220mAh)
1: S+(RS485)
2: S-(RS485)
3: 24G
4: Terminal input P00
5: Terminal input P01
6: Terminal input P02
7: Terminal input P03
8: Terminal input P04
9: Terminal input P05
10: 24G
11: 24P (external 24V output)
-
12: Terminal output P40
13: Terminal output P40C
14: Terminal output P41
15: Terminal output P41C
16: Terminal output P42
17: Terminal output P42C
TB1
External Terminal
Block
18: Terminal output P43
19: Terminal output P43C
Detail outline of the external terminal block (TB1) is shown below.
RS
48
5 (+)
단자
: Mo
db
us-RTU
마스
터
RS485 (-)
단자
: Mod
bus
-RTU
마스
터
24
GND
24
GND
24
V
출력
Terminal
input acts
as NPN.
Terminal
input acts
as PNP.
4 TB outputs
RS48
5 (-) Te
rminal : Mod
bus RT
U
RS48
5 (+) Te
rminal : Mod
bus RT
U
6 TB outputs
Outpu
t