3.5 Operating the inverter using the control
terminal block
3.5.1 Setting parameter values for control terminal
block operation
Step
Keypad instructions
Keypad display
1
Set FUN 01 to “Terminal 1”.
2
Set FUN 02 to “Analog”.
3
Set the maximum motor speed.
4
Define Ai1 (analog input at V1).
5
Select a range for the Ai1 input (V1) source:
-
-10–10 V / 10–-10 V
-
0–10 V / 10–0 V