Detailed Specification of Communication Profile Specific Objects
22
5 Detailed Specification of
Communication Profile Specific
Objects
5.1 Device Type
The following SDO indicates the device type of the communication module.
Index
0x1000
Data type
UNSIGNED32
Sub-index
0x00
Access
RO (Read-only)
Data
0x00010192
Consisting of two words; the upper word indicates the
Frequency Converter (0x01) and the lower word indicate the
Drive Profile DSP402 (0x0192).
5.2 Error Register
Error registers provide error-related information for the communication module.
Index
0x1001
Data type
UNSIGNED8
Sub-index
0x00
Access
RO
Data
Bit
Information
0
Generic error
1
Current-related trip (current error)
2
Voltage-related trip (voltage error)
3
Temperature-related trip (temperature error)
4
Reserved
5
Reserved
6
Reserved
7
Manufacturer-specific