LRX™ FRESNEL
Check for the latest manual updates at www.lrx-lighting.com
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
4
4
Excessive exposure to high intensity white light may cause fatigue and skin
irritation.
High energy light output will burn skin and ignite combustible materials. Do
not operate in the proximity of materials that are adversely affected by heat
or light.
Failure to adhere to these warning may result in serious burns or
irreversible skin/eye damage.
Do not look directly into the light during operation.
Personal or flammable objects may not be within 40m (131 feet) of the lens
during operation.
Lamp housing becomes extremely hot when in operation, avoid contact.
When fixtures are mounted in close proximity to one another, care must be
taken so that output energy from one fixture is not directed at another
fixture or electrical cabling.
IMPORTANT: Please follow the operating instructions of the ballast.
FIXTURE ADDRESSING
Fixture addressing is performed at the rear of the fixture hanger assembly.
The fixture can be programmed to operate in DMX mode or FIXTURE mode
(for use with the hand controller). Because each LRX fixture requires sixteen
DMX channels for operation, FIXTURE mode is merely a convenient way of
skipping DMX channels in 16 channel increments, beginning with DMX
channel #001. Additionally, fixture mode provides power to a connected hand
controller, which is also designed to work in 16 channel increments.
DMX Connector pin out: (also see important note below)
Pin 1 = ground
Pin 2 = Data negative
Pin 3 = Data positive
Pin 4 = 12VDC negative
Pin 5 = 12 VDC positive
When the LRX fixture is in FIXTURE mode, pins 4 & 5 on the DMX IN
connector become energized to 12VDC to supply power to the hand controller.
No power is supplied to pins 4 & 5 when in DMX mode. Ensure that fixture is
in the correct mode prior to connecting DMX lines. Always connect the hand