Repeat Delay
When using a repeater, it may be necessary to add a delay between pages when paging multiple pagers to
allow the repeater time to repeat the signal and detect the next one. To add repeat delay:
1. Press SETUP.
2. Press F1 (MORE) until asked for an authorization code.
3. Enter 5-6-7-8-9.
4. Press F1 (MORE) until the display shows 1: Repeat Delay.
5. Press 1 (1: Repeat Delay).
6. Select F1 (ON) to enable or OFF (F2) to disable.
7. Select F4 (DONE) when finished.
ID Span
In very large systems up to 9999 Guest pagers can be paged. To do this, ID Span is required. This function
disables normal System ID functions except for Staff Paging and allows the programming of Guest Pagers
from 1000 to 9999.
To use ID Span:
1. Press SETUP
2. Press F1 (MORE) until asked for an authorization code
3. Enter 5-6-7-8-9
4. Press F1 (MORE) until the display shows 1: ID Span
5. Press 1 (1: ID Span)
6. Select F1 (ON) to enable or F2 (OFF) to disable
7. Select F4 (EXIT) when finished
Dry Contacts
The Dry Contact are contacts or switches that are connected through a wire to the T7400A, for example:
Doorbell. This sensor can send a message to the pager when an event occurs (e.g., alarms if a door is
opened). Default setting for the Contact Sensor is OFF. To program the Contact Sensor (Dry Contact):
1. Press SETUP.
2. Press F1 (MORE) until asked for an authorization code.
3. Type 5-6-7-8-9.
4. Press F1 (MORE) until the display shows 1: Dry Contact.
5. Select 1 (1: Dry Contact).
6. At the Contact Menu screen – select 1 (1: Prog
Contacts).
7. Select contact to program – press 1 (1: Contact #1) or
2 (2: Contact #2.).
8. The Screen will show if Contact Sensor is currently on
or off:
• Press F1 to turn the function ON.
• Press F2 to turn the function OFF.
9. If select ON, select for the sensor to set as:
Long Range Systems
20
T7400A User Manual
Dry Contacts