1 Europe VIIG-H05VVF3G1,00-C13; Italy I/3/16-H05VVF3G1,00-C13; Switzerland 12G-H05VVF3G1,00-C13; 

UK BS13/13-H05VVF3G1,00-C13; Japan 498GJ-VCTF3X1,25-C13; USA, Canada, Mexico HG/

TR-SJT3X18AWG-C13 (connect to Hospital grade receptacle in hospital environment)

A T T E N T I O N

 

>

CONTROL SCREEN

 

>

ERGOLIFT HEAD

DESCRIPTION OF THE CONTROLS

2

PREC

AUTIONS OF USE

3

 

>

WARNING

 

>

IMPORTANT SAFETY INFORMATION

All safety precautions must be observed whilst using electrical equipment. Please read all 

safety notices and precautions prior to use of the equipment.

DANGER

 - TO MINIMIZE THE RISK OF ELECTRICAL SHOCK:

• Always disconnect the equipment from the electrical supply outlet after use and before 

cleaning and maintenance.

• Check that the supply voltage of the unit indicated on the data plate complies with 

the mains voltage.

• The unit must be connected by the power cord

1

 supplied to a grounded outlet in accordance 

with current electrical standards. Electrical adapters must not be used with this equipment.     

• The equipment must not be left unattended 

whilst connected to the electrical supply.

• Disconnect the unit from the electrical 

supply if it is not going to be used for a long 

period.

• This device can be used by children 8 years 

of age and older and those with reduced 

physical, sensory or mental abilities or lack 

of experience and knowledge if they have 

been instructed or instructed to use the 

hearing aid. safe way and understand the 

dangers. involved.

• Never use the unit for purposes other than 

those recommended by LPG Systems. Only 

use the parts supplied with your unit or 

those recommended by LPG

 

Systems.

• Never use the equipment if: 

-  the electrical power cord or outlet  

  is damaged. 

-  the equipment does not function correctly. 

-  the equipment is damaged or has fallen  

  or been dropped. 

-  the equipment has been exposed  

  to excessive humidity. 

In such cases, return the equipment to an 

approved LPG

 

Systems service centre.

• Do not move the unit by pulling the electrical 

power cord.

• Do not move the device by holding on to the 

accessories holder. It is recommended to 

remove it everytime you move the device and 

to use the handle provided.

• Fully unwind the electrical power cord and 

keep it away from warm surfaces.

• Never use the equipment if the ventilation 

ports are obstructed. Ensure that the 

ventilation ports are kept clear of dust or 

other contaminants.

• Do not allow solid debris, liquid or other 

foreign bodies to fall or be sucked into the 

unit, as these could cause damage.

• Never use the equipment on a dusty, uneven 

floor, or in a moist atmosphere.

• The device must be positionned on a flat and 

rigid surface.

• Never use the equipment in the presence of 

aerosols or oxygen.

• Before disconnecting the unit from the 

electrical supply, set all controls to the ‘off’ 

position and unplug the unit.

• It is prohibited to modify this equipment 

without prior authorisation from the 

manufacturer.

 

TO MINIMIZE THE RISK OF BURNS, FIRE, ELECTRICAL SHOCK OR INJURY

TOUCH-SCREEN 

TREATMENT CHAMBER

ERGOLIFT HEAD

FLAPS

Содержание Mobilift M6 Connect

Страница 1: ...ator s manual contains the operating description basic maintenance instructions to be performed periodically and the safety instructions With the aim to continuously provide satisfaction your device i...

Страница 2: ...E N T I O N PACKAGE CONTENTS TABLE OF CONTENTS 1 DESCRIPTION OF THE UNIT 4 2 DESCRIPTION OF THE CONTROLS 6 3 PRECAUTIONS OF USE 7 4 MAINTENANCE 10 5 ERGOLIFT HEAD 16 6 TROUBLESHOOTING 19 7 TECHNICAL S...

Страница 3: ...d blood microcirculation 2 Improve skin quality scarring and fibrosis 3 Fight against the effects of skin aging wrinkles sagging skin fine lines appearance of fat firmness elasticity complexion puffin...

Страница 4: ...ted to use the hearing aid safe way and understand the dangers involved Never use the unit for purposes other than those recommended by LPG Systems Only use the parts supplied with your unit or those...

Страница 5: ...areas mucous membranes the genitals or breasts Do not treat a patient with an infectious disease a growing tumour a phlebitis a wound or an infected area Do not treat a patient with skin cancer a visi...

Страница 6: ...clement weather This symbol indicates temperature limits This symbol indicates relative humidity limits This symbol means Danger High Voltage M A I N T E N A N C E 4 IDENTIFICATION RATING PLATE M A I...

Страница 7: ...command screen displays the following icon fig 1 Access the filter change menu as follows Select the maintenance menu by pressing the icon indicated fig 2 Select the filter menu by pressing the icon...

Страница 8: ...E T I E N 4 Replacing flaps once the flaps no longer treat the skin properly they must be replaced They should be replaced after every 20 hours A personal face endermologie kit for use by the patient...

Страница 9: ...RS Only the LIFT20 and LIFT10 treatment chambers can be connected to the Ergolift head They can be connected and disconnected by a simple push pull action Lift 20 chamber with removable Lift 20 flaps...

Страница 10: ...er with sterile or drinking water for at least 1 minute using a large volume of water approximately 8 liters Repeat twice for a total of 3 rinses 4 Dry the treatment chamber and flap 5 Clean the stora...

Страница 11: ...ation Unit fitted with patented treatment heads Device designed for uninterrupted use You have recently acquired an appliance distributed by LPG Systems or an LPG Systems approved distributor It is th...

Страница 12: ...and operating instructions failure to carry out maintenance and or negligence in maintaining the appliance and or its filter cartridges connection to a faulty electricity supply or a non earthed elect...

Страница 13: ...TIVES AND MANUFACTURER DECLARATION ELECTROMAGNETIC EMISSIONS MOBILIFT M6 CONNECT is intended for use in the electromagnetic environment specified below The MOBILIFT M6 CONNECT customer or patient shou...

Страница 14: ...terruptions IEC 61000 4 11 0 UT 0 5 cycle A 0 45 90 135 180 225 270 et 315 0 UT 1 cycle 0 70 UT 25 30 cycles 0 0 UT 250 300 cycles 0 UT 0 5 cycle A 0 45 90 135 180 225 270 et 315 0 UT 1 cycle 0 70 UT...

Отзывы: