LIMITATION AND EXONERATION OF LIABILITY

The warranty is limited to the replacement of the components of the device which comply with 
conditions described above.

Under no circumstances shall LPG Systems be liable for any loss or damage as a result or in 
connection with the device and/or its use, including any financial loss, loss of margin, loss of 
use, etc. 

This clause shall apply under any and all legal basis.

Whenever the above restriction may not be applicable or enforceable, LPG Systems liability 
shall be limited to the price for the device and/or the service.

W

ARRANTY

8

 

>

GENERAL WARRANTY CONDITIONS 

(CONT’D)

W

ARRANTY

8

Warranty exclusions:

• Damage occurring during transportation. 

Transportation of this equipment and/or 
spare parts is at the recipient’s own risk. 
Before taking delivery, it is the recipient’s 
responsibility to verify the state of the goods 
and to make a claim against the transport 
company in the manner usual in the delivery 
country. 

•  Non-observance of the installation and 

operating instructions, failure to carry  
out maintenance and/or negligence  
in maintaining the appliance and/or its filter 
cartridges, connection to a faulty electricity 
supply or a non-earthed electricity supply  
or a power supply whose voltage is different 
to the one indicated on the appliance. 

• If an appliance is sold before the end of the 

warranty period, the warranty is transferred 
to the purchaser for the remaining warranty 
period, on the condition that: 
I  The original invoice is provided. 
II   That the initial vendor is informed 

of the sale.

• Modification, mounting of accessories  

or dismantling of the equipment. 

• Any operation and/or intervention not 

specified in the LPG Systems Operating 
Instructions and performed on the 
equipment by the purchaser/user and/or  
any party not approved by LPG Systems. 

• Use of consumables, spare parts, 

inappropriate components or parts not 
supplied by LPG Systems. 

•  Blockage of the appliance through aspiration 

of a foreign body. 
 

• Normal wear and tear of any of the 

equipment’s parts resulting from  
normal usage. 

• Damages or default resulting of accidental 

events (falls, impacts...). 
Damages or default resulting of natural 
disasters (lightening, water damages...), 
fire, negligence or abuses.

Содержание Mobilift M6 Connect

Страница 1: ...ator s manual contains the operating description basic maintenance instructions to be performed periodically and the safety instructions With the aim to continuously provide satisfaction your device i...

Страница 2: ...E N T I O N PACKAGE CONTENTS TABLE OF CONTENTS 1 DESCRIPTION OF THE UNIT 4 2 DESCRIPTION OF THE CONTROLS 6 3 PRECAUTIONS OF USE 7 4 MAINTENANCE 10 5 ERGOLIFT HEAD 16 6 TROUBLESHOOTING 19 7 TECHNICAL S...

Страница 3: ...d blood microcirculation 2 Improve skin quality scarring and fibrosis 3 Fight against the effects of skin aging wrinkles sagging skin fine lines appearance of fat firmness elasticity complexion puffin...

Страница 4: ...ted to use the hearing aid safe way and understand the dangers involved Never use the unit for purposes other than those recommended by LPG Systems Only use the parts supplied with your unit or those...

Страница 5: ...areas mucous membranes the genitals or breasts Do not treat a patient with an infectious disease a growing tumour a phlebitis a wound or an infected area Do not treat a patient with skin cancer a visi...

Страница 6: ...clement weather This symbol indicates temperature limits This symbol indicates relative humidity limits This symbol means Danger High Voltage M A I N T E N A N C E 4 IDENTIFICATION RATING PLATE M A I...

Страница 7: ...command screen displays the following icon fig 1 Access the filter change menu as follows Select the maintenance menu by pressing the icon indicated fig 2 Select the filter menu by pressing the icon...

Страница 8: ...E T I E N 4 Replacing flaps once the flaps no longer treat the skin properly they must be replaced They should be replaced after every 20 hours A personal face endermologie kit for use by the patient...

Страница 9: ...RS Only the LIFT20 and LIFT10 treatment chambers can be connected to the Ergolift head They can be connected and disconnected by a simple push pull action Lift 20 chamber with removable Lift 20 flaps...

Страница 10: ...er with sterile or drinking water for at least 1 minute using a large volume of water approximately 8 liters Repeat twice for a total of 3 rinses 4 Dry the treatment chamber and flap 5 Clean the stora...

Страница 11: ...ation Unit fitted with patented treatment heads Device designed for uninterrupted use You have recently acquired an appliance distributed by LPG Systems or an LPG Systems approved distributor It is th...

Страница 12: ...and operating instructions failure to carry out maintenance and or negligence in maintaining the appliance and or its filter cartridges connection to a faulty electricity supply or a non earthed elect...

Страница 13: ...TIVES AND MANUFACTURER DECLARATION ELECTROMAGNETIC EMISSIONS MOBILIFT M6 CONNECT is intended for use in the electromagnetic environment specified below The MOBILIFT M6 CONNECT customer or patient shou...

Страница 14: ...terruptions IEC 61000 4 11 0 UT 0 5 cycle A 0 45 90 135 180 225 270 et 315 0 UT 1 cycle 0 70 UT 25 30 cycles 0 0 UT 250 300 cycles 0 UT 0 5 cycle A 0 45 90 135 180 225 270 et 315 0 UT 1 cycle 0 70 UT...

Отзывы: