LPG Mobilift M6 Connect Скачать руководство пользователя страница 11

2 1

2 0

TECHNIC

AL SPECIFIC

A

TIONS

7

 

>

TECHNICAL SPECIFICATIONS

The Mobilift M6

®

 Connect i is marked         as a medical device by virtue of Annex II of 

regulation 93/42/EEC (applicable standards IEC 60601-1 Ed3 and related standards)

Your  Mobilift  M6

®

  Connect  device  requires  special  care  concerning  the  EMC,  it  must  be 

installed and service according to the information provided in this user guide. Portable and 

mobile  RF  communication  devices  must  not  be  used  within  30cm  of  your  device,  they  can 

cause  undesired  operation.  The  use  of  other  treatment  heads  than  those  provided  by  LPG 

Systems may result in increased emissions or decreased immunity of the device. 

Your Mobilift M6

®

 Connect device should not be used adjacent to or stacked with other medical 

devices. Interference may occur near equipment marked with the following symbol: 

Your Mobilift M6

®

 Connect doesn’t manage essential performances. 

For more information concerning the electromagnetic compatibility, refer to “Electromagnetic 

compatibilty” appendix.

W

ARRANTY

8

 

>

GENERAL WARRANTY CONDITIONS

Dimensions: length x width x height:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 x 26 x31 cm
Net weight:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.5 kg
Maximum set depression:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 kPa (350 mbar)
Cooling:  . . . . . . . . . . . . . . . . . . . . . . . . . .by mechanical ventilation incorporated into the pump
Protection index:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP20
Electrical protection class:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Operating temperature:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +10°C to +30°C
Storage temperature:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -20°C to +70°C
Electrical features:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100-240V / 50-60Hz / 80 VA
Wifi:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4Ghz b/g/n
EIRP:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100mW

Operating environment:
Ambient temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10 to 30° C for normal operation.
Ambient relative humidity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 to 75% without condensation.
Atmospheric pressure:   . . . . . . . . . . . . . . . . . . . . . . . . . . no significant influence for operation.
Max altitude:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,500 m

Environmental characteristics of transport and storage: 
Ambient temperature:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -20°C to +70°C 
Ambient relative humidity:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 to 90% without condensation 
Atmospheric pressure: . . . . . . . . . no significant influence of ambient conditions in operation

Unit fitted with patented treatment heads.
Device designed for uninterrupted use.

You  have  recently  acquired  an  appliance 
distributed by LPG Systems or an LPG Systems 
approved distributor.

It is the purchaser/user’s responsibility to find 
out  from  the  local  authorities  the  conditions 
and professional qualifications required before 
using  the  appliance.  The  purchase  of  this 
equipment implies the legal acceptance by the 
purchaser/ professional user of these general 
warranty conditions.

If the appliance was sold to you by an approved 
LPG  Systems  distributor,  the  purchaser/
user  should  refer  to  the  supplier’s  warranty 
conditions. These may in no way increase the 
undertakings  made  by  LPG  Systems  in  these 
present warranty conditions. The warranty can 
only  be  implemented  and  is  only  valid  if  the 
warranty  slip  has  been  duly  filled  out  and 
returned to LPG Systems within two weeks of 
delivery,  irrespective  of  the  country.  Warranty 
slips  that  are  only  partially  completed  will  be 
rejected.

The  appliance  is  guaranteed  against 
manufacturing  flaws  and  defects  in  the  raw 
materials. 

The  warranty  extends  for  the  shorter 
of  the  following  two  periods:  one  (1)  year 
OR  two  thousand  (2,000)  hours  of  use  from 
the  invoice  date.  During  this  period,  LPG 
Systems  undertakes  to  exchange  or  repair 
free  of  charge,  as  quickly  as  possible,  any 
part  that  LPG  Systems  acknowledges  as 
defective,  however  LPG  Systems  does  not 
undertake  to  replace  the  entire  appliance.
Traveling  and  living  expenses  for  our  
technicians  and  transportation  costs  of  the 
appliance  or  parts  to  and  from  the  aftersales 
service  workshop  are  not  covered  by  this 
warranty.

Replacements  and  repairs  performed 
within  this  warranty,  with  or  without 
immobilization  of  the  equipment,  shall  not 
have  the  effect  of  extending  the  warranty 
period.  Replaced  parts  become  the  property 
of  LPG  Systems  or  the  approved  distributor. 
No compensation shall be paid for loss of use. 

Subject to other conditions hereafter, warranty 
shall  apply  if  the  purchaser/professional 
user  has  allowed  LPG  Systems  to  proceed  to 
necessary repair works.

Содержание Mobilift M6 Connect

Страница 1: ...ator s manual contains the operating description basic maintenance instructions to be performed periodically and the safety instructions With the aim to continuously provide satisfaction your device i...

Страница 2: ...E N T I O N PACKAGE CONTENTS TABLE OF CONTENTS 1 DESCRIPTION OF THE UNIT 4 2 DESCRIPTION OF THE CONTROLS 6 3 PRECAUTIONS OF USE 7 4 MAINTENANCE 10 5 ERGOLIFT HEAD 16 6 TROUBLESHOOTING 19 7 TECHNICAL S...

Страница 3: ...d blood microcirculation 2 Improve skin quality scarring and fibrosis 3 Fight against the effects of skin aging wrinkles sagging skin fine lines appearance of fat firmness elasticity complexion puffin...

Страница 4: ...ted to use the hearing aid safe way and understand the dangers involved Never use the unit for purposes other than those recommended by LPG Systems Only use the parts supplied with your unit or those...

Страница 5: ...areas mucous membranes the genitals or breasts Do not treat a patient with an infectious disease a growing tumour a phlebitis a wound or an infected area Do not treat a patient with skin cancer a visi...

Страница 6: ...clement weather This symbol indicates temperature limits This symbol indicates relative humidity limits This symbol means Danger High Voltage M A I N T E N A N C E 4 IDENTIFICATION RATING PLATE M A I...

Страница 7: ...command screen displays the following icon fig 1 Access the filter change menu as follows Select the maintenance menu by pressing the icon indicated fig 2 Select the filter menu by pressing the icon...

Страница 8: ...E T I E N 4 Replacing flaps once the flaps no longer treat the skin properly they must be replaced They should be replaced after every 20 hours A personal face endermologie kit for use by the patient...

Страница 9: ...RS Only the LIFT20 and LIFT10 treatment chambers can be connected to the Ergolift head They can be connected and disconnected by a simple push pull action Lift 20 chamber with removable Lift 20 flaps...

Страница 10: ...er with sterile or drinking water for at least 1 minute using a large volume of water approximately 8 liters Repeat twice for a total of 3 rinses 4 Dry the treatment chamber and flap 5 Clean the stora...

Страница 11: ...ation Unit fitted with patented treatment heads Device designed for uninterrupted use You have recently acquired an appliance distributed by LPG Systems or an LPG Systems approved distributor It is th...

Страница 12: ...and operating instructions failure to carry out maintenance and or negligence in maintaining the appliance and or its filter cartridges connection to a faulty electricity supply or a non earthed elect...

Страница 13: ...TIVES AND MANUFACTURER DECLARATION ELECTROMAGNETIC EMISSIONS MOBILIFT M6 CONNECT is intended for use in the electromagnetic environment specified below The MOBILIFT M6 CONNECT customer or patient shou...

Страница 14: ...terruptions IEC 61000 4 11 0 UT 0 5 cycle A 0 45 90 135 180 225 270 et 315 0 UT 1 cycle 0 70 UT 25 30 cycles 0 0 UT 250 300 cycles 0 UT 0 5 cycle A 0 45 90 135 180 225 270 et 315 0 UT 1 cycle 0 70 UT...

Отзывы: