Trouble Shooting

 

Maintenance

 

Contacting  surfaces  of  the  electromagnet  and  armature  plate  must  be  kept  free  of  contaminating  materials. 
Surfaces should be cleaned periodically with a non

-

abrasive cleaner. Do not spray the electromagnet or armature 

plate surface with any lacquer chemical, this will create problems with the release of the magnetic lock and armature 
plates.

 

Problem

 

Possible Cause

 

Solution

 

 

Door will not lock

 

No DC voltage to lock. Loose wire on 
terminal strip.

 

Check power supply and wiring to 
magnetic lock.

 

 

Reduced holding force

 

Bad physical contact between armature 
plate and face of magnet.

 

Incorrect voltage jumper setting.

 

Ensure  mating  surfaces  are  clean  and 
in  proper  alignment  and  the  armature 
plate floats freely.

 

Check  magnetic  lock  for  low  voltage 
or wrong voltage setting.

 

 

Delay in door release

 

Circuit  switch  is  not  between  magnetic 
lock and power source. Secondary diode 
installed  across magnetic lock.

 

Re

-

wire circuit switch between magnetic 

lock and power source.

 

Remove any installed diode. Voltage 
spike protection is on the PCB.

 