26
NOTE
Remember, you cancel any scan mode at anytime by pressing the
16/9
or
SCN
key.
To start an All Scan
To scan through all available channels, press and hold the
SCN
key for
three seconds.
ALL SCN
will appear on the display. The radio now will
scroll through every available channel as it scans.
A noisy channel that interrupts the scanning can be temporarily elimi-
nated from the scan list by holding down the
MEM
key. The channel re-
ceiving the signal will be skipped, allowing the scanning to continue
uninhibited. Turning the radio off
and
on again will restore all the
channels back to the
A
LL
S
CAN
memory list.
To start a Memory Scan
To scan through channels in the memory scan list, press the
MEM
key,
then push the
SCN
key. If you are in a different scanning mode, you
must stop the scan before switching to a
M
EMORY
S
CAN
. In that case,
press
SCN
|
MEM
|
SCN.
To add channels to the memory scan list, use the
↑
↓
keys to tune in
each of the channels you want to monitor. As you tune in each channel,
depress
MEM
for three seconds to add it to the memory list. The
MEM
Annunciator will appear, letting you know the channel has been added
to memory..
While in the
MEM
scan mode, touch the
WX
key to toggle the
W
X
A
LERT
function off and on
.
The scan will stop when a channel picks up a sig-
nal. The scan will not continue until the input signal stops. To stop
scanning, press the
SCN
key or the
16/9
key. Press in the
PTT
button
exits the scan mode at the last channel display.
To start a Priority Scan
Pressing the
SCN
key activates the
P
RIORITY
S
CAN
mode.
P SCAN
will ap-