31
LGC-2000 remote connection to NMEA 2000 buss.
NOTE:
An existing operational NMEA 2000 buss will already have
terminators in place and will already be powered. If you're connecting
to such a network, you won't need the terminators or extension cable
provided.
Do not add
terminators or power to a functional NMEA
2000 buss!
When the LGC-2000 is connected to the unit (directly or indirectly), it
will begin providing GPS signal information.
Power Connections
Your unit comes with a power/data cable that splits into three ends,
each with several exposed wires (shown in the following figure). The
end with 4 wires (blue, yellow, orange and shield) is a Data cable that
connects to a NMEA 0183 interface. The end with three wires (red,
black and shield) is a power cable that connects to a NMEA 2000 buss.
The thicker three-wire cable (red, black and white) is the Power Supply
for your unit (and optional external speaker connection for some units).
The Power/Data cable for this unit.
Depending on your configuration, you may not use all of these wires.
The following segments include instructions for installing all the wires
that you will use with this unit.
Caution
All of the wires in the power/data cable have bare ends for
easier installation. The bare ends on any unused wires could
cause an electrical short if left exposed. To prevent this, you
should cover the individual wire ends – either by capping them
with wire nuts or wrapping them with electrical tape. (You
should cut off the bare wire before taping off the ends.)
To NMEA 2000
network port
LGC-2000
To unit
Data Cable wires: blue,
yellow, orange and shield
Power Supply wires:
red, black and white
NMEA 2000 Power wires:
red, black and shield