![Lowrance GlobalMap 7200C Скачать руководство пользователя страница 149](http://html.mh-extra.com/html/lowrance/globalmap-7200c/globalmap-7200c_operation-instructions-manual_1942912149.webp)
141
Calibrate is highlighted on the device configuration menu (left). Cali-
bration menu (right) with calibration instructions listed at the top.
3-Point Calibration
3-point calibration is designed for tanks that vary in shape from the top
to the bottom. You can begin calibration at any point in the 3-point
process, but we recommend starting calibration with an empty tank.
In a 3-point calibration, you will set three points, one each for empty,
half and full levels.
1. Press
MENU| MENU
, use
↓
↑
to select
NMEA
2000
and press
ENT
.
2. Highlight
B
US
S
ETUP
and press
ENT
, which will open the Bus Configu-
ration menu. A list of network devices will be at the top of the page. 3.
Select the EP-15 Fluid Level and press
ENT
.
4. Press
↓
to select
C
ALIBRATE
and press
ENT
. The Device Calibration
menu will appear.
5. Highlight
N
UM
P
TS
, press
ENT
and select
3
. Press
ENT
.
6.
Make sure your tank is empty, then highlight
F
LUID
L
EVEL
and press
ENT
.
Select
E
MPTY LEVEL
and press
ENT
.
7.
Select
C
ALIBRATE
and press
ENT
. The following message will appear:
Empty Level Calibration Completed
. Press
ENTER
.
8.
Add half a tank of fuel, highlight
F
LUID
L
EVEL
and press
ENT
.
Select
H
ALF LEVEL
and press
ENT
.
9.
Select
C
ALIBRATE
and press
ENT
. The following message will appear:
Half Level Calibration Completed
. Press
ENT
.
10. Fill up the tank, then
highlight
F
LUID
L
EVEL
and press
ENT
.
Select
F
ULL LEVEL
and press
ENT
.
11
.
Highlight
C
ALIBRATE
and press
ENT
. The following message will ap-
pear:
Full Level Calibration Completed
. Press
ENT
, then press
EXIT
re-
peatedly to get back to the main display.