Technical Manual LÖWEN Dart HB8
01/2019
68
7.
If you want to delete the credit counter readings, press [TEST] button on the controller board. Player 1
– 2 display will then show
SEL tP
.
NOTICE
This feature is not available for country setting Spain.
8.
Press [PLAYER CHANGE] button to exit.
6.2.4
Statistics Printout
The values shown in the statistics mode (StA) can be read and printed with a DATAreader or other suitable
devices.
1.
Press [TEST] button on the controller board.
tSt
appears in the TEMP SCORE display.
2.
Press [GAMES] or [OPTIONS I] button until
StA
appears in the TEMP SCORE display.
3.
Press [OPTIONS II] button to confirm.
4.
If required:
If you have activated the security code, enter the code now (compare chapter 6.1.4 P04 - SEL SEC:
Security Code)
SEL CN
appears in player 1 – 2 display, and
S01
in the TEMP SCORE display.
5.
Plug the DATAreader into the VDAI socket (cashbox compartment, left side). Data transfer starts
automatically, according to the individual DATAreader settings (short/ middle/ long – with/ without
deletion). Please check the LÖWEN DATAreader manual for detailed information.
6.
Unplug the DATAreader as soon as the data transfer is finished, and the DATAreader has generated a
bleep.
7.
Press [PLAYER CHANGE] button to exit.
Statistics data will be printed as follows:
Bookkeeping Data
Shows number of coins per coin channel, total number of thrown-in coins, number of paid credits, and
number of bonus credits.
Game Statistics
Shows number of players, number of credits played, and programmed price.
Machine ID Code
8 digit machine identification code assigning the machine with its corresponding printouts (MACHINE ID
CODE, GAME NUMBER).
Printout Number (Receipt Number)
Each time statistics are printed, this number is increased by one (RECEIPT #). This number cannot be
changed.