ACSP2004-IG-GTF
20A Single-circuit Surge Suppressor with Ground Transient Filter
Lowell Manufacturing Company
• 100 Integram Drive • Pacific, Missouri 63069 U.S.A.
Call
800.325.9660, 636.257.3400 •
Fax
636.257.6606 •
Click
www.lowellmfg.com
Lowell makes every effort to provide accurate information and reserves the right to change specifications and/or improve manufacturing methods.
Download and print this spec from www.lowellmfg.com to insure that you have the most current information
1c-107
pg 4 of 4
ACSP2004-IG-GTF wiring using only factory-installed receptacle
ACSP2004-IG-GTF wiring using factory-installed rece aux. receptacle
ACSP2004-IG-GTF wiring for permanent (hardwire) installation (no receptacles)
ACSP2004-IG-GTF wiring using only factory-installed IG receptacle
ACSP2004-IG-GTF wiring using factory-installed IG rece aux IG receptacle
ACSP2004-IG-GTF wiring for permanent (hardwire) installation (no receptacles)
Factory installed
duplex receptacle
1) Connect input (line)
to pigtails.
Any knock-
out may be utilized.
2) Install blank cover.
1) Cut leads to factory
installed
receptacle. Splice
in leads from
auxiliary receptacle.
Alternate Method: Remove receptacle from plate. Connect auxiliary receptacle leads to
screw terminals. Re-install receptacle to plate.
Safety Ground (see *Note)
Neutral (white)
Line (black)
Typical Wiring ACSP2004IG-GTF
(with safety ground only)
Auxiliary
Receptacle
(shown connected)
2) Cut or disconnect
wires to factory
installed receptacle.
4) Connect load
(output). Any
knockout may
be utilized.
5) Connect Green
wire from board
to isolated
ground.
6) Install blank
cover on each
side.
Factory installed
isolated-ground
duplex receptacle
Alternate Method: Remove receptacle from plate. Connect auxiliary receptacle leads to
screw terminals. Re-install receptacle to plate.
3) Connect safety
ground (green)
from load side.
4) Connect load
(output). Any
knockout may
be utilized.
4) Connect Green
wire from board
to isolated
ground.
6) Install blank
cover on each
side.
Typical Wiring ACSP2004IG-GTF
(with independent isolated ground)
Ground Stud
2) Cut or disconnect
wires to factory
installed receptacle.
1) Connect input (line)
to pigtails.
Any knock-
out may be utilized.
2) Install blank cover.
1) Cut leads to factory
installed
receptacle. Splice
in leads from
auxiliary receptacle.
Safety Ground (green)
Neutral (white)
Line (black)
Isolated Ground
(green/yellow stripe)
Auxiliary
Receptacle
(shown connected)
1) Connect input (line)
to pigtails.
Any knock-
out may be utilized.
Safety Ground (see *Note)
Neutral (white)
Line (black)
1) Connect input (line)
to pigtails.
Any knock-
out may be utilized.
Safety Ground (green)
Neutral (white)
Line (black)
Isolated Ground
(green/yellow stripe)
*Note: Connect bonding
jumper and green striped
wire from GTF.
*Note: Connect bonding
jumper and green striped
wire from GTF.
3) Connect safety
ground from load
side.