Troubleshooting:
PROBLEM CAUSE
CORRECTIVE
ACTION
Machine will not start.
Emergency stop switch(s) activated either
control box or top head assembly.
No incoming power.
Defective start pushbutton
Check that both E-stop switches are not
engaged.
Check machine fuses and plant receptacle.
Re-place pushbutton.
Box jamming in machine.
Box is out of range of machine.
Box is voided and head is crushing it.
Tape cartridge problems.
Side belt drive belting worn.
Do not run out of spec box.
Adjust head balance regulator.
Check tape cartridge troubleshooting.
Replace drive belts.
Top head assy. won’t move.
Lock knob engaged
Guide bearing / wear pad tight..
Head lifting spring failure.
Check that lock knob is not engaged.
Adjust guide bearing / wear pads.
Replace head lifting spring.
Side drive will not move.
Adjustment chain broken.
Side drive screw binding.
Check that chain and adjust.
Grease adjustment screw.
Drive belts are slipping.
Belts are not tensioned.
Belts are worn.
Adjust tensioner until spring is collapsed.
Replace drive belts.
Chapter
8
Содержание LD3SBF
Страница 1: ...Little David Case Sealer LD3SBF Side Belt Drive Uniform Case Sealer Version D Operator sManual ...
Страница 31: ...ASSEMBLY DRAWINGS AND SCHEMATICS Chapter 10 ...
Страница 39: ......
Страница 40: ......
Страница 41: ...MACHINE AVAIABLE SPECIAL OPTIONS Chapter 11 ...