![Lotus PCID-44ET Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/lotus/pcid-44et/pcid-44et_instructions-for-installation-and-use-manual_1941214054.webp)
54
GB
IE
FAULT MESSAGES FROM THE GENERATOR (E1)
Error.
No.
Name
Cause
Corrective action
E1
01
Hardware over current
Unsuitable pan material
Use suitable pan material
Wrong or defective coil
Check the coil
E1
02
No inductor current
Inductor connection failure
Connect the inductor properly
E1
03
IGBT temperature too
high
Air routes blocked
Fan clogged, temperature
sensor of IGBT defective
Clear air routes
Clean fan, check fan rotation
E1
04
Cooking zone
temperature too high or
too low
Pan empty
Remove pan, switch off and wait a
couple of minutes until the cooking
field has cooled down
Temperature sensor faulty
The sensor must be replaced
Power board faulty
Replace the generator
E1
05
Control unit failure
Control unit defective or
wiring defective
Check or replace operating unit,
check wiring harness to unit
Digital control has faulty ID
Switch the generator off, adjust the
DIP-switches correctly
Control unit faulty
Replace the control unit
E1
06
Internal temperature
too high
Air routes blocked
Fan clogged, temperature
sensor defect, close exterior
heat sources
Clear air routes
Clean fan
E1
07
Coil temperature
Coil temperature to high
Remove pan, switch off and wait a
couple of minutes until the cooking
field has cooled down
Temperature sensor faulty
The sensor must be replaced
E1
08
Mains phase failure
Breakdown of mains phase or
mains quality insufficient
Check mains supply
E1
10
Communication error
Failure on LIN or CAN-Bus,
no connection between
keyboard and generator
Disconnect from mains and check
connection
E1
11
Initialisation error
Needless control unit
connected
Connect control unit to the correct
control plug
Digital control has faulty ID
Switch the generator off, adjust the
DIP-switches correctly
Failure while initialising of the
hardware
Just wait, the device will be reset
approx. every 30 sec.
E1
13
Mains connection
error
Mains voltage is too high or
too low
Check mains connection
E1
14
Mains adaptor error
Mains voltage is too high or
too low
Check mains connection
E1
15
Empty pan protection
Mains error
Switch off the main fuse, wait a
few seconds and switch on
Empty pan
Remove pan, switch off and wait
for a couple of minutes until the
cooking field has cooled down
Defective temperature sensor of
the coil
The sensor must be replaced