13
Operating Instructions for
LTS 138 / 150 SAC
A
ll data is without guarantee, errors and changes are reserved
.
LOTUS TRANSFER PRESS SOLUTIONS GmbH & Co. KG
Parameter adjustment
Standardprogramm
(00)
Please press button
S
for 25 seconds. The display confirms access to the program by
showing up
00
followed by flashing and an audible signal.
In order to choose programs 01
, 02 and 03
please press button
S
again.
Flex-Program (01)
•
Press button
S
•
The display shows up
01,
followed by the audible signal and blinking
•
On the display the preset parameters appear:
160°C
and
15
seconds
Flock-Program (02)
•
Press button
S
•
The display shows up
02,
followed by the audible signal and blinking
•
On the display the preset parameters appear:
150°C
and
15
seconds
Sublimationprogram (03)
•
Press button
S
•
The display shows up
03,
followed by the audible signal and blinking
•
On the display the preset parameters appear:
200°C
and
60
seconds
The operator may change the preset parameters with buttons
„+“ and „-„
.
The modified parameters may be saved directly by pressing button
S
and may
always be recalled and altered again.
The preset temperature may be modified in each program (01…02…03) plus or
minus 20 °C. For the standard program however, temperatures between 0°C and 250°
may be adjusted.
Display signals
In case of failures, the new control board
TS2 3P
gives different signals in order to
discover and resolve the problem immediately.
•
If
111
appears on the display and the light blinks, followed by an acoustic
signal, the temperature sensor is defect or not connected with the control board.
•
If
000
appears on the display and the light blinks, followed by an acoustic
signal, the temperature ranges about 15°C because of a default. The control
board must be checked.