INSTALLATION

Translation of the original instructions

14

Warning

 

Installation  operations,  any  conversion  to  other  types  of  gas  and  start-up  must  only  be
performed by qualified personnel, in accordance with current regulations.

 

Gas systems, electrical connections and premises where the appliances are installed must comply with
current regulations in the country of installation; in particular, the appliance must be installed in a room with
good ventilation, if possible under a suction hood to ensure complete evacuation of the exhaust gases
formed during combustion. The air required for combustion is 2 m3/h per kW of installed power. The
appliance can be installed alone or in series with other appliances in our production range. A minimum
distance of 10 cm between appliances must be respected to prevent contact with any walls made of
flammable material; furthermore, appropriate measures should also be adopted to ensure the thermal
insulation of flammable parts, such as the installation of heat shields; take special care to ensure that
appliances are installed in an appropriate and safe manner. The support feet can be adjustable in height and
any unevenness can therefore be eliminated.
 

ELECTRICAL CONNECTION

Caution

 

In accordance with international provisions, when connecting the appliance an automatic
device must be installed up-line of it so that the device can be fully disconnected from the
mains; this device must have a contact aperture of at least 3 mm.

The connection terminal is located behind the rear wall. Proceed as follows to install the power supply cable:
 

·

Remove the rear panel.

·

Pass the new connection cable through the cable gland, connect the leads to the corresponding terminal

on the terminal block and fasten them securely.

·

Lock the cable with the cable gland and refit the panel. The earth/ground lead must be longer than the

others so that if the cable gland breaks it is disconnected after the power cables.

 

Note

 

Make sure that the mains voltage complies with the data on the appliance's ID plate and that there is
good conductivity to earth/ground. Pay attention when inserting leads to ensure they do not obstruct
the normal course of work and routine appliance cleaning operations. Also make sure that the power
cable is never pulled taut and is not placed in contact with sources of heat.

Note

 

The connection cable must have the following characteristics: it must be silicone type (to
withstand temperatures of 180 °C), and must have an appropriate cross-section for the power
of the appliance (see technical data table).

 

EQUIPOTENTIAL

 
The appliance must be connected to an equipotential system. The connecting screw is located on the rear of
the appliance and is marked by the yellow symbol above it.
 

Warning

 

The manufacturer is not liable for and does not indemnify damages caused by incorrect
inadequate installations that do not comply with these instructions.

Содержание F13T-94ET

Страница 1: ...ELECTRIC FRYERS FOR PROFESSIONAL USE F18 94ET F2 18 98ET F25 94ET F2 25 98ET F13T 94ET F2 13T 98ET F2 8 94ET F2 8T 94ET Model LIBR ISTR F90E Code 563008003 Review 1 Edition date 28 03 2019 Language English LOTUS S p A Via Calmaor 46 31020 San Vendemiano 39 0438 778020 39 0438 778277 ...

Страница 2: ...e electrical and electronic equipment 11 2 3 Technical data table 11 3 INSTALLATION 13 3 1 Delivery checks 13 3 2 Removing the packaging 13 3 3 Mechanical installation 13 3 4 Electrical gas connections 13 4 INSTRUCTIONS FOR USE 15 4 1 General information 15 4 2 Turning the appliance on off 15 4 3 Safety thermostat 15 4 4 Emptying the tank 16 4 5 Top appliances bowl emptying 16 5 MAINTENANCE 17 5 1...

Страница 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 F 9E A Data Plate B Electrical connection ...

Страница 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 F T A Data Plate B Electrical connection ...

Страница 5: ...INTRODUCTION Translation of the original instructions 5 1 2 Components FIG B ROTARY RESISTANCE 1 O rings 2 Rotary heating element ...

Страница 6: ...T 94ET F2 13T 98ET F2 8 94ET F2 8T 94ET C 1 Switch 2 Microswitch 3 Power supply terminal board 4 Power switching terminal block 5 Resistor switching terminal block 6 Heating element 7 White indicator light 8 Green indicator light 9 Contactor 10 Thermostat 11 Safety thermostat ...

Страница 7: ...nal instructions 7 WIRING DIAGRAM F18 94ET F2 18 98ET F25 94ET F2 25 98ET D 1 Switch 2 Microswitch 3 Power supply terminal board 4 Heating element 5 White indicator light 6 Green indicator light 7 Contactor 8 Thermostat 9 Safety thermostat ...

Страница 8: ...anslation of the original instructions 8 Wiring diagram reference table MODELS TERMINAL BOARD 1 TERMINAL BOARD 2 F18 94ET D F2 18 98ET D D F25 94ET D F2 25 98ET D D F13T 94ET C F2 13T 98ET C C F2 8 94ET C F2 8T 94ET C ...

Страница 9: ...INTRODUCTION Translation of the original instructions 9 1 3 Example installation of the appliance ...

Страница 10: ...e electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be held liable for any damage caused if the system is not connected to ground earth Before carrying out any cleaning or maintenance tasks on the equipment unplug it from the electricity mains In the event...

Страница 11: ...on The penalties provided for in the event of improper disposal of RAEE Waste Electrical and Electronic Equipment are those provided for by the national transpositions of European Directives 2012 19 EU 2 3 Technical data table Electrical technical data table F S90E MODEL DIMENSIONS POWER SUPPLY MAXIMUM POWER kW MAXIMUM ABSORPTION A POWER SUPPLY CABLE silicon type F18 94ET 40x90x90h 400V 3N 50 60Hz...

Страница 12: ...L INFORMATION Translation of the original instructions 12 DESIGN ASSEMBLY TRANSFORMATION ELECTRICAL LINKING TERMINAL BLOCK PERNIONS see technical data table POWER SUPPLY CONNECTION HEATING ELEMENT CONNECTION ...

Страница 13: ... not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating material and or neutral elements between them 3 4 Electrical gas connections Before being offered for sale on the market the appliance was subjected to gas and electrical testing as required The ...

Страница 14: ... of it so that the device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows to install the power supply cable Remove the rear panel Pass the new connection cable through the cable gland connect the leads to the corresponding terminal on the terminal block and fasten them secu...

Страница 15: ...cleaning or maintenance operation Fill the tank with oil up to the lower reference mark 4 2 Turning the appliance on off Turn on the switch located upstream of the appliance Turn the knob from 0 to the desired position between 110 and 190 C the white and green indicator lights will turn on The green indicator light indicates that the appliance is powered The white indicator light indicates that th...

Страница 16: ...hat during the emptying stage the oil does not overflow and does not represent a hazard We recommend filtering the oil every day at the end of work and changing it when necessary Turn the oil drain cock into the horizontal position Take special care if the oil is hot Note Pay close attention to the distance between the appliance and the edges of the basin 4 5 Top appliances bowl emptying The user ...

Страница 17: ...ce and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personnel When replacing the electrical components of the machine and the electrical panels scrupulously follow the technical characteristics for the replacement component indicated on the component itself T...

Страница 18: ...ng the heating element Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket until it can be removed At this point the heating element can be removed from inside the bowl pushing it towards the draught diverter Also replace the 3 o rings see point 1 in figure B and apply a bit of grease to facilitate the operation Note It is recommended to replace the ...

Страница 19: ...s are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For minor cleaning a mild washing up liquid solution may also be used Do not wash the appliance with jets of water under pressure Avoid using detergents containing abrasive powders or bleaches of any kind...

Отзывы: