background image

• Shut water supply by turning the water valve to the right
• Separate the strainer by using a coin to turn it to the left. 
• After cleaning the filter in running water turn it back to the right to assemble it  

and open the water valve. 

Water supply valve

Disconnect the power plug. 

Shut the valve by turning it to the right.

When pressing the drain button located on the side of the body unit, 
the water in the tank will completely drain into the toilet bowl. 

• This electronic toilet seat has considered the user’s  

convenience in that the water can be drained easily 
without removing the unit from the toilet seat. 

Draining button

Check if the power cord is plugged in securely.  

Adjust the (                 ) button to “low”to prevent water from freezing. 

If the product is not used for a long period of time, 
please disconnect the power cord and 
drain the water from the internal unit. 

• Beware to not use any bathroom cleaning detergents such as benzene acid 

chemical detergent on the seat exterior.

- Using any type of chemical products or rough scrubbers on the electronic toilet seat surface, 

which is made out of plastic material can either damage or change its color. 

• Do not spray water directly or use a shower hose on the main body unit. 

- Can cause fire or damage to the unit.

• When cleaning, the power cord must be unplugged from the power outlet,  

and make sure water does not contact the cord and/or outlet.

• After cleaning, use a soft cloth to dry the unit. 

•Please perform the actions below without sitting on the toilet seat

- On control panel press and hold the ‘WASH’ button for three(3) seconds and the water nozzle will extend. 
- To clean use a soft bristled brush(tooth brush) or a soft cloth. Upon completion press and hold the 

‘STOP’ button and the nozzle will retract back to its original position and will perform it’s self-cleaning function.

- Upon completion of these two steps the toilet seat can be used.

Do not use any cleaning products such as Oxy Clean.

Water filter

(Strainer)

19

18

10

Maintenance

Cleaning the body unit

Cleaning the nozzle

Cleaning the water filter(strainer)

11

Draining water from tank 

12

Maintenance for winter season

Please do not keep this product outdoors during the winter    
as the cold temperature may damage the product. 

Water supply valve

Содержание ATS-800

Страница 1: ...improvements Importantsafeguards generalcautions are information that can protect the user from safety hazards and alsopreventlosses Pleasebesuretoreadthemanualcorrectlyforproperusage L o t u s H y g...

Страница 2: ...designations Installation and cautions Initial operation Separation of the unit from toilet bowl Basic operation Detailed operation Maintenance Draining water Winter usage Trouble shooting Specificati...

Страница 3: ...ending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover Whenever the adapter is used it must be held in place by the screw This appliance has to be...

Страница 4: ...her when cleaning the product or detaching the unit from the toilet bowl Failure to do so can cause an electric shock Do not use a damaged power cord or a loosely fitted electric outlet This can cause...

Страница 5: ...use low degree burning Special precautions should be taken for children those who cannot adjust the temperature and those who have sensitive skin For plumbing For product fixation Installation instruc...

Страница 6: ...toilet mounting holes Put the bolt into the bolt case and align it with the top of the base plate Insert bolt with bolt case onto the base plate After this is done hold the bolts slide it into the bo...

Страница 7: ...ectronic toilet seat and turn the water valve to the left to open it See if there is any leaking from the water hose connection Re install the toilet seat and lid that was separated when installing th...

Страница 8: ...ing button the display light will change to allow the adjustment Seat temperature Low High Low High Low High Low High Low High Cautions Cautions Average maintenance time for warm water This product ca...

Страница 9: ...up to 5 levels When using the wash functions use front back buttons to adjust the nozzle to fit to your body LED level Front I Back Front I Back 17 16 Nozzle position adjustment Warm air dryer adjust...

Страница 10: ...rubbers on the electronic toilet seat surface which is made out of plastic material can either damage or change its color Do not spray water directly or use a shower hose on the main body unit Can cau...

Страница 11: ...d high If someone has already used the wash function wait about 3 minutes to use it Sit on the seat for approximately 3 minutes and then use it Tighten the bolt do not over tighten See if the skin sen...

Страница 12: ...e applicable periods specified below following the terms of this warranty Lotus Hygiene Systems Inc replacement will be warranted to the original purchaser of the products The Parts Warranty If the pa...

Отзывы: