1 2
Installation
Travis Industries
9 3 5 0 8 1 0 8
0 4 0 1 9 9
Installation Example: Direct "Through-the-wall" Installation
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAAA
AAAAAAAAAAAAA
A
A
A
A
A
A
A
A
A
3” Minimum
9” Minimum
AA
AA
A
A
AAAAAAAAAAAAA
AAAAAAAAAAAAA
Floor Protection
6” Minimum
A
House Shield (used to protect exterior wall from soot
discoloration) is HIGHLY RECOMMENDED
12” Minimum
Horizontal Rain Cap
Wall Thimble (note
3” clearance
between vent and
combustibles)
Outside Air
Type "L"
Vent
12”
Minimum
A
A
A
A
A
A
A
A
A
A
A
A
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
3” Minimum
16-1/2”
9-1/4”
Floor Protection
Seal each vent
section (including
adapters, elbows,
etc...) by injecting a
liberal amount of
500° F. RTV
silicone into the gap
between sections.
500° F. RTV
Silicone