First please turn off the water supply and electricity supply. Remove the decorative panel, 
you will see the hot tank cover (check Picture 4). Use tool to open the hot tank cover, then 
put clean water into hot tank. Use soft cloth or soft brush to clean the hot tank. After that, 
take off the hot tank drain stopper at the bottom of machine. When drain out all the water, 
put the stopper in place. The cleaning process of hot water tank finished. Please clean the 
unit with soft cloth dipped in warm water or neutral detergent. To clean the display panel 
and decorative panel, please use soft dry cloth.   
Do  not  use  rough  detergents,  concentrated  washing  liquid,  solvent  or  anything  that  may 
scratch the machine materials (such as steel wool, steel balls, etc.). 
Attention: If it connects with power supply when you cleaning the machine, make sure not 
make the back of machine damp.   
 

Note:

 If you find there are scales in hot tank, you can put 5% citric acid into tank to clean 

the scales. Move machine out of table for around 20cm, hook the dust cover by hand and 
pull it out. 

                 

 

                                                               

    Picture 10   

 

9.3.

 

Clean the Dust Cover   

Move machine out of table for around 20cm, hook the dust cover by hand and pull it out. Use 
close or brush to clean the dust on it, then put it back.   
 

Note: 

To  clean  the  dust  cover  regularly  can  help  machine  to  keep  good  ventilation 

performance, making sure each functional modules can work efficiently.   
 

9.4.

 

Clean Machine   

Please clean the unit with soft cloth dipped in warm water or neutral detergent. To clean the 
display  panel  and  decorative  panel,  please  use  soft  dry  cloth.  Do  not  use  rough  detergents, 
concentrated washing liquid, solvent or anything that may scratch the machine materials (such 
as steel wool, steel balls, etc.). 
 

Attention: 

If  it  connects  with  power  supply  when  you  cleaning  the  machine,  make  sure  not 

make the back of machine damp.   

 

 
 

Содержание GR310MB

Страница 1: ...18 User Manual Table Top Mini Bar Water Dispenser GR310MB Please read this manual carefully before using...

Страница 2: ...nect with Overflow discharge 6 Operation Page 9 10 6 1 Attentions before Using 6 2 Connect to Power Supply 7 Different Functional Systems Page 10 11 7 1 Filtration System 7 2 Hot Water System 7 3 Cold...

Страница 3: ...em Sterilization syste Controlling System ACF ACF UF ACF RO Ozone UV Electronic Mechanical Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 Option 8 Note This model have different functi...

Страница 4: ...witch 2 Indicator Light 11 Heating Switch 3 Water Outlet 12 Maintenance cover 4 Front Panel 13 Vent 5 Drip Tray Cover 14 Water Inlet Connector 6 Side Panel 15 Waste Water Drain Connector RO version 7...

Страница 5: ...18 2 2 Control Panel Instruction 1 Child Lock 2 Water Button Cold Water Button 3 Extra Hot Button 4 Cooling Icon 5 Extra Heating Icon 6 Water Making Icon 7 Ozone Icon 8 Heating Icon...

Страница 6: ...Rated General Current 220 V AC 50 Hz 1000 W 5 8A 2 Heating System Hot Tank Volume Heating Power Heating Capacity Hot Water Temp 1 8L 900 W 10L h 90 3 Cooling System Cold Tank Volume Cooling Power Rat...

Страница 7: ...18 4 Electrical Schematic Remark You may not be informed should there are some changes on technical parameter...

Страница 8: ...re all there a three way ball valve elbow quick connector PE pipe 5 2 1 Please shut off the water supply and take off the faucet by turning counterclockwise see picture 1 Picture 1 5 2 2 Please wrap t...

Страница 9: ...e Note This clause is only apply to the machine with RO system inside If you machine doesn t have RO system please ignore this clause 5 4 Connect with Overflow Discharge Please refer to the Picture 3...

Страница 10: ...Note This clause only applies to the machine with ACF filtration system or UF filtration system 7 1 2 RO Filtration System After connected with electricity supply all the icons on the display panel s...

Страница 11: ...e This clause only applies to the machine with ozone system 7 4 2 UV System When getting cold water the UV system automatically work The UV icon lights on after getting cold water the UV system still...

Страница 12: ...same time the cooling icon shin on a frequency of 2 Hz push water button or any other button to stop getting hot water if doesn t push any buttons 1 minutes later machine stop cold water outlet automa...

Страница 13: ...nsert the front buckle of decorative panel into the front panel then press the decorative panel Picture 4 9 1 3 How to replace filter After remove the decorative panel you will see there are one or tw...

Страница 14: ...UV Open Please find the UV replace tool on the accessory bag Insert UV Replace Tool into UV hole push out the buckle in the hole as the same time turn the UV counter clockwise to take off UV See pict...

Страница 15: ...2 1 Clean Water Tank First please turn off the water supply and electricity supply Remove the decorative panel you will see the water tank cover check Picture 4 Open the water tank cover add clean wat...

Страница 16: ...chine make sure not make the back of machine damp Note If you find there are scales in hot tank you can put 5 citric acid into tank to clean the scales Move machine out of table for around 20cm hook t...

Страница 17: ...en tank and faucet and the water tank is not a pressure tank The machine can make hot water with high temperature children are forbidden to use machine without accompanied by adults The machine is for...

Страница 18: ...here are ice in the cold tank Turn on cooling switch Check it 30 minutes later Turn off the power supply start the machine again after 2 hours Leakage Drip tray is full Water leakage inside of the mac...

Отзывы: