Picture 5
Open— Turn the filter out (Counter clockwise)
Close—Install filter (clockwise)
Picture 6
9.1.4.
How to replace UV
After remove the decorative panel you can see on the top there is UV installed. (see picture
4) . Please do accordingly as following to replace UV.
Taking off UV(Open).
Please find the “UV replace tool ” on the accessory bag. Insert UV
Replace Tool into UV hole, push out the buckle in the hole, as the same time, turn the UV
counter clockwise to take off UV. See picture 7.
Install UV(Close).
Hold UV and insert UV into cold tank. Then turn UV clockwise, and
when you feel the buckle auto blocked, the UV installation finishes. See picture 7.
Picture 7
Note:
This clause only applies to the machine with UV system.
9.1.5.
How to change Ozone generator