23
interruption in the
refrigeration
circuit or there is
no gas.
to check that the gas
expansion temperature is
correct.
The machine temperature is
too cold.
The thermo
regulator is not set
to the correct
position.
Adjust the thermo regulator
as indicated in chapter n° ?.
The lighting does not work.
The power supply
cable is damaged
or interrupted.
Remove the bulb cover, see
Fig. ?, slide out the bulb pins
from their seat, and replace
the bulb
Replace the bulb starters,
located in the motor
compartment, and check the
bulb power supply unit.
The ventilation does not
work.
The fan blades are
blocked.
Contact a qualified technician
in order to identify the cause
behind the fault.
The block fan –
open door switch
does not work.
Check that the magnet placed
on the door is correctly
positioned. If necessary, bend
the magnet slightly unit it is
in the correct position.
The evaporator
temperature is not
could enough.
Contact a qualified technician
to check that the refrigeration
circuit works perfectly, and
then check the evaporation
temperature by following the
instruction in chapter?.
Gurgling and blowing noises caused by the refrigeration circuit are normal.