4

Safety First ..............Don't  assume anything............. Always double check.

If in doubt, ask someone who is QUALIFIED to assist you in the subject.

Warnings

Please carefully read this manual and all warnings. Install the meter ONLY when you are sure
that you’ve covered  all  aspects.

Where the product is intended for “UL” installations, removal or
addition of option boards is not permitted.

Check that the model number and supply voltage suit your application before
you install the meter.

Connect the meter according to current IEE regulations, IEC61010 &
NFPA:70 National Electric Code in USA.

This meter is for Installation class II service only. This means it
has exposed electrical and power terminals. You must install it in a
suitable fire enclosure which will also protect users from electric shock

We designed this meter  for Pollution-Degree 2 environments only.

Power supplies to this equipment must have anti-surge (T) fuses rated at 400mA for
230V supply, 400mA for 110V supply or 2A for DC supplies in the range 11-30VDC.
Only Siba fuses in series 189500, c

UL

us listed according to file #E167295 are

accepted for this service under the terms of UL listing. A switch or circuit breaker, clearly
marked as a disconnecting device, must be included close to the installation.

Don’t touch any circuitry after you have connected the meter, because there may be
lethal voltages on the circuit board.

Only adjust on-board switches or connections with the power turned off

Make sure all screw terminals are tight before you switch the meter on.

Only clean the meter’s front  with a soft damp cloth. Only lightly dampen with water.
Do not use any other solvents. The behind-panel case may be cleaned with a dry cloth
only, use no liquid or solvent on it.

!

!

!

!

!

!

Содержание INT2-H

Страница 1: ...outputs 0 none AL2 2 relays AL4 4 relays Serial data 0 none 232 RS232 485 RS485 Display colour R Red G Green Power AC 100 240V AC DC 11 30V DC Mounting 0 Standard panel DIN DIN rail mounting Caution...

Страница 2: ...foregoing warranty shall not apply to defects resulting from 1 Improper or inadequate maintenance by the buyer 2 Unauthorised modification or misuse 3 Operation outside the environmental specification...

Страница 3: ...ic input functions 21 Logic Input connections and front buttons 22 Menu Timeout adjustment 23 Reverse Mirror display setting 24 Bootup Routine choices 25 Language selection for user interface 26 Error...

Страница 4: ...rs fromelectric shock We designed this meter for Pollution Degree 2 environments only Power supplies to this equipment must have anti surge T fuses rated at 400mA for 230V supply 400mA for 110V supply...

Страница 5: ...hutdown periods you may have to to wait several weeks for an equivalent replacement or we may have no stock at the time you urgently need it You mayalso needto pay extra carriagecharges ifyou wanta fa...

Страница 6: ...240 VAC or 11 30VDC These meters are designed to mount into a protective enclosure which will protect users from contact with power and signal wiring Theseunits mustbe installedfully assembled and mus...

Страница 7: ...of meter U Bracket Bracket screw 1 of 2 Left side of meter case U Bracket Bracket screws U Bracket Bracket screws Slide the meter with gasket into the panel cutout Securing into the panel Re fit the...

Страница 8: ...using the 4 buttons Output functions include isolated 16 bit 4 20mA 0 10V 10 to 10V RS232 RS485 and up to 4 alarms with a wide choice of alarm functions Install the meters in a suitable protective ele...

Страница 9: ...sealed IP65 all round and is supplied with the meter in stalled for you to wire to via 3 cable glands It comes complete with SPC4 splashproof cover We also offer a dual version of this enclosure which...

Страница 10: ...5mm2 Tighten screw terminals to 7 0 lb in torque 0 8 Nm torque Cable insulation voltage rating Cables shall have an insulation voltage rating of at least 380V continuous Wire preparation We recommend...

Страница 11: ...cts 5V DC 1mA Warning Disconnect all power before exposing the rear of the meter Connectors and options Connectors may be present evenif outputoptionsarenot installed Refertoratinglabel toseeinstalled...

Страница 12: ...the cable is properly cancelled Mixing destinations carelessly amongst the twisted pairs can actually worsen noise performance 3 The cable should be routed away from noisy wiring and devices such as...

Страница 13: ...al sensors please be sure to use one twisted pair for each display and sensor Do NOT use a wire from one pair for signal positive and a wire from another pair for signal negative as this will prevent...

Страница 14: ...Easy orAdvanced mode How to choose menu mode Set1 Set2 Output Alarms Digit OK Max Min Reset Lockout Switch must be OFF Press together briefly Set1 Set2 Output Alarms Digit OK Max Min Reset Press brie...

Страница 15: ...ess of the UP button will select a newbrightness level There are 7 brightness levels to choose from Default Full brightness Set1 Set2 Output Alarms Digit OK Max Min Reset Press to accept 1 2 3 Done Di...

Страница 16: ...nce last accident Timer Mode HH MM Timer Mode MM SS Timer Mode SSSS Timer Mode SSSSS t Timer Mode MMMM Timer Mode HH MM SS Timer Mode dd MM yy Timer Mode MM dd yy Lockout Switch must be OFF OFF Circui...

Страница 17: ...igit OK Max Min Reset Press to accept Done Press 3 seconds Display shows input channel choices Display format 24Hr leading zeros 9am shows 09 00 12Hr leading zeros 9am shows 9 00 Daylight saving time...

Страница 18: ...ices Counting direction UP Up counting normally from zero dn Down counting normally from preset Down Count action on reaching 0 Neg Y Display will go below 0 on down count neg n Display will stop at 0...

Страница 19: ...1 Jan 12 Dec Set the date 1 1st 31 31st Set the hour must be GMT or UTC Set the minutes The time will brighten and the 4 leds to the right of the display will flash At exactly 14 59 press the OK butt...

Страница 20: ...one This feature is available in Easy and Advanced Modes Display shows defs n Defaults no Press the DOWN button to change the display to defs y Defaults Yes if you want to return to default conditions...

Страница 21: ...the existing function for Contact Closure 1 After you have set CC 1 you will get the prompt CC 2 to allow you to set Contact Closure 2 function and when you have set CC 2 you will get the prompt CC 3...

Страница 22: ...ontacts or self cleaning contacts for best long term reliability Logic Inputs Power Signal I P Excitation 1 2 3 4 5 6 7 8 9 10 11 12 13 Normally open disables front panel Tare Peak Valley and Reset bu...

Страница 23: ...OFF Press together briefly Set1 Set2 Output Alarms Digit OK Max Min Reset Press repeatedly until you see dLAY XX where XX is the delay in seconds Choices are dLAy 1 0 dLAy 20 dLAy 30 dLAy 60 default 1...

Страница 24: ...put Alarms Digit OK Max Min Reset Press OK button briefly and repeatedly until you see rEV d 0 Default or rEV d 1 Set1 Set2 Output Alarms Digit OK Max Min Reset Press briefly to toggle 1 2 3 4 Set1 Se...

Страница 25: ...ton is pressed Lockout Switch must be OFF Press together briefly Set1 Set2 Output Alarms Digit OK Max Min Reset Press OK button briefly and repeatedly until you see boot 0 or boot 1 or boot 2 or boot...

Страница 26: ...witch must be OFF Press together briefly Set1 Set2 Output Alarms Digit OK Max Min Reset Display shows UI Eng Default for User Interface English or UI FrA for User Interface French 1 2 3 Set1 Set2 Outp...

Страница 27: ...and may also be erratic This could be caused by contact bounce if you are using a contact closure input be sure that the contact debounce is enabled dbnc on 4 Total is not saved on power down in a DC...

Страница 28: ...n in the diagram If the meter doesn t yet have an output option board the top screw may not yet be fitted 4 Slide the electronic boards out throught the front of the case You can easily separate the u...

Страница 29: ...o dispose of it It must not be thrown away with general rubbish If you are unable to dispose of this item locally you may send it to us for recycling Conditions 1 We will only accept items of our manu...

Страница 30: ...hermal equilibrium Front sealed IP65 Optional cover SPC4 for IP67 Power 100 240 VAC 45 to 60Hz or 11 30 VDC optional Burden 10VA maximum Accuracy Accuracy better than 10 seconds per month DS3231SN Bat...

Страница 31: ...s Optional outputs now described in their own dedicated manuals DIN Rail mounting option added Cabling guidance added 3 February 2011 Version F00 21 Software released New bootup routine added increase...

Страница 32: ...ncludes relay output wiring All signal cabling shall be screened The screen shall only be terminated to the power earth terminal at the meter end of the cable Declared as true and correct for and on b...