Page 8

Features

Calibration Counter / Tamper detector

An internal totaliser counts each calibration. To see the cal count, press the left-
hand button at power-on. The ‘CAL XX’ value appears for a second or two after
you switch the meter on.  The number starts at 00 and can go up to FF (255
counts). It doesn’t count changes of setpoints.  It stores the total in non-volatile
memory which can’t be reset, so is useful for keeping track of the meter’s cali-
bration history.

Reset Command

The reset command clears the accumulated total. It may be accessed either
from the front panel or by external contact closure command.

Front Panel key reset command

1) Link terminal 7 to terminal 10
2) Set lockout switch ‘ON’
3) Press Down Arrow key to reset display

Remote contact closure resetting

1) Connect a normally-open contact closure switch between terminals 7 and 10
2) Set lockout switch  ‘ON’

Display ‘Actual Current’ Command

The ‘display rate’ input allows you to see the instantaneous current. It may be
accessed either from the front panel or by external contact closure command.

Front Panel key Current display command

Press the UP arrow key to see actual current.

Remote contact closure rate display command

1) Connect a normally-open contact closure switch between terminals 7 and 9
2) When you make a contact closure between terminals 7 and 9, the display
    will show the intantaneous value, for as long as the contact is closed.

Содержание INT-AH

Страница 1: ...2003 IEC 1010 89 336 EEC Ampere Time Display Meter Plating Current monitor with pulsed outputs Model INT AH Rev AH 1 1 Software Version DIGIT Min ZERO SPAN dp ZERO SPAN d p MAX MIN TARE ALARMS OK RES...

Страница 2: ...Notes...

Страница 3: ...Calibration Tamper detection 8 Connections 5 Decimal point position selection 6 Declaration of Conformity 17 Failsafe alarm setting 10 General description 3 Getting Started 4 Installing options 9 Intr...

Страница 4: ...cover damage caused by misuse or accident IMPORTANT If the meter is a vital component in your process you may wish to buy a spare to cover possible failure or accident as we cannot guarantee instant...

Страница 5: ...heck that model number and supply voltage suit your application before you install the meter Don t touch any circuitry when the meter is powered because lethal voltages may be present on the circuit b...

Страница 6: ...n when fitted with appropriate plug in option boards Alarm outputs 2 and 4 give pulsed outputs of 100mS each time a batch total has been reached The front panel has a 6 digit 7 segment window for disp...

Страница 7: ...hesignalandpowercables totheappropriatescrewterminalconnectors Check that you are using the correct terminals or you may cause damage to the meter Do not connect any output or alarm cabling yet Apply...

Страница 8: ...unt should be located in the low voltage unswitched return line to minimise common mode noise These connectors are only used when options are fitted Connections E Common No function Disp Current Reset...

Страница 9: ...or ampere hour applications this is normally the rated current of your shunt If the value is correct press the OK button otherwise use the DIGIT key to select digits and the UP or DOWN arrow keys to a...

Страница 10: ...you want to count ampere HOURS b Set InHi 75 00 mV c Set rd Hi to 200 0 d Set InLO to 0 00 mV e Set lo Rd to 0 2 You have a 60mV shunt rated at 100 Amperes and want to display ampere hours to the nea...

Страница 11: ...ommand Front Panel key reset command 1 Link terminal 7 to terminal 10 2 Set lockout switch ON 3 Press Down Arrow key to reset display Remote contact closure resetting 1 Connect a normally open contact...

Страница 12: ...board We strongly suggest that you use anti static precautions toprevent damage to the semiconductors The board assemblies will look something like this Always be careful to connect the pins to socket...

Страница 13: ...ill see two small screws one on each surface Remove both screws Now clip off the front bezel and slide the meter assembly carefully out via the front of the case The relay board plugs into the main bo...

Страница 14: ...e until its LED is flashing then press the ALARM key for more than 3 seconds You will see one digit is brighter than the others You can change its value using the UP DOWN buttons and then select other...

Страница 15: ...sion Dual slope 10 conversions per second Resolution 1 in 63000 max over full range Display update rate 2 5 readings per second Memory of total E2PROM with 10 year storage No batteries required Plug I...

Страница 16: ...Page 13 Record of Revisions Changes 31July2003 Released...

Страница 17: ...Notes Page 14...

Страница 18: ...Page 15 48 0 96 0 92 0 22 0 102 0 12 0 DIGIT Min ZERO SPAN dp ZERO SPAN d p MAX MIN TARE ALARMS OK RESET OUTPUT AL1 AL2 AL3 AL4 0 O P 100 O P Lineariser Max...

Страница 19: ...Page 16 12 0 102 0 22 0 44 0 92 0 45 0...

Страница 20: ...ngshallberoutedseparatelytopowercarryingcabling includesrelayoutputwiring Allsignalcablingshallbescreened Thescreenshallonlybeterminatedtothepowerearthterminal This is to confirm that the Product cove...

Отзывы: