SECTION 4. DISASSEMBLY AND SERVICE
- 46 -
b. INSPECTION
CARBON BRUSH/ SLIP RING
Remove the carbon brushes from the brush holder.
Check the brush for length, wearing condition or
any other defect. Replace if the length is less than
5 mm (0.20in).
NOTE:
z
Connect the Red wire lead to the positive (+)
side of the brush holder.
z
Avoid damaging the brushes when removing
and installing the brush holder.
Visually inspect the slip rings for free dust, rust or
other damage. If necessary, wipe them with a clean
lint-free cloth. If they are rusted or damaged,
remove the rotor and wipe with fine emery cloth.
FIELD WINDING
Remove the brushes and measure resistance
between the slip rings.
If the specified resistance is obtained at the slip
rings, but not at the brush terminals, clean or
replace the brushes.
If the specified resistance is not obtained at the slip
rings, clean or replace the rotor.
RESISTANCE
5000 40.35-49.3
Ω
6500 47.88-58.52
Ω
8000 48.25-59.88
Ω
Slip ring - END
∝