SECTION 4. DISASSEMBLY AND SERVICE
- 32 -
CHARGING COIL
Measure the resistance between the wire terminal
and ground.
If the resistance is not as specified, replace the
charging coil.
STARTER SOLENOID (6500 model only)
Connect a 12 V battery between the starter terminal
and the solenoid body and check for continuity
between the terminals. Continuity should exist
when the battery is connected and not exist when
the battery is disconnected.
If the resistance is not as specified, replace the
starter.
RESISTANCE 3.5±0.5
Ω
RESISTANCE >1
M
Ω