Battery
Inspect the level of the battery fluid and see if
the terminals are tight. Add distilled water if
the fluid level is low.
Replenishing the battery fluid
A poorly maintained battery will corrode and
discharge quickly. The battery fluid should be
checked at least once a month.
1. The level should be between the upper and
lower lever marks. Use only distilled water if
refilling is necessary.
2. Disconnect the negative (-) lead.
3. Disconnect the positive (+) lead and re-
move the battery.
4. When the machine is not to be used for a
month or longer, remove the battery and put
it in a cool, dark place. Thoroughly recharge
the battery before reusing.
5. If the battery is to be stored for a longer
period than the above, check the specific
gravity at least once a month and recharge
the battery when it is too low.
6. Always make sure the connections are right
when putting the battery back in the machine.
Make sure the breather hose is properly con-
nected and is not damaged or obstructed.
Fuse replacement
1. The fuse case is placed under the seat.
2. If the fuse is blown, turn off the main switch
and equip a new fuse of the specified
amperage. Then turn on the switches. If the
fuse immediately blows again, consult your
dealer.
50