![Lombardini ECOWIND 350 C - EUR 12V Скачать руководство пользователя страница 130](http://html.mh-extra.com/html/lombardini/ecowind-350-c-eur-12v/ecowind-350-c-eur-12v_assembly-and-installation-manual_1938340130.webp)
56
THIS MANUAL IS PROPRIETY OF
ECOWIND by LOMBARDINI
- ALL FORMS OF REPRODUCTION, PARTIAL OR OTHERWISE, IS STRICTLY PROHIBITED
G
B
H
I
C
D
D
Fig. 106
Fig. 105
Fig. 108
Fig. 107
C
C
P
P
S
P
P
Warning!!
Before performing the operation mentioned above, make sure that the condensation drainage pipe
(H) is securely fastened to the plastic coupling (I) on the back split’s base (fig. 106 ).
Warning!!
INSTALL KIT “ANTIPOLLUTION FILTER D” (SUPPLIED WITH THE EQUIPMENT*) Fig. 108 WITH
SELF-THREADING SCREWS C, AS INDICATED IN FIG. 107
Step Description
13
Secure the split
S
to the counter frame
O
by sliding it onto the 4 Stud M6
P
and then fasten it using Ø 6 washers and
the M6 AB nuts provided (fig. 105 )
ASSEMBLY AND INSTALLATION
- 3
Warning!!
Check properly that in all the lenght of drain hose condensation between split and external cab
“THERE IS NOT ANY BOTTLENECK OR TORSION ON RUBBER HOSE”. This inobservance, could
make a serious problem of water inside the cab !!!