background image

3.6 

Operation 

environment

3.7 

Operation 

Notices

Maintenance

Troublesho-

oting
4.1 

Maintenance

▲ Height above sea level ≤1000 M

▲ Operation temperature range -10

+40°C

▲ Air relative humidity is below 90 %( 20°C)

▲ Preferable site the machine some angles above the floor level, the maximum angle does not 

     exceed 15

.

▲ Protect the machine against heavy rain AND against direct sunshine. 

▲ The content of dust, acid, corrosive gas in the surrounding air or substance cannot exceed normal 

     standard. 

▲ Take care that there is sufficient ventilation during welding. There must be at least 30cm free distance 

     between the machine and wall.

▲ Read Section §1 carefully before starting to use this equipment.

▲ Connect the ground wire with the machine directly.

▲  Ensure that the input is three-phase: 50/60Hz, 400V ±10%.

▲  Before operation, none concerned people should not be around the working area and especially 

     children. Do not watch the arc in unprotected eyes.

▲  Ensure good ventilation of the machine to improve Duty Cycle.

▲  Turn off the engine when the operation finished for energy consumption efficiency.

▲  When power switch shuts off protectively because of failure. Don’t restart it until problem is resolved. 

     Otherwise, the range of problem will be extended.

▲  In case of problems, contact your local dealer if no authorized maintenance staff is available!

In order to guarantee safe and proper operation of welding machines, they must be maintained 

regularly. Let customers understand the maintenance procedure of welding machines. Enable 

customers to carry on simple examination and inspections. Do your best to reduce the fault rate and 

repair times of welding machines to lengthen service life of arc welding machine. Maintenance items in 

detail are in the following table.

● Warning: for safety while maintaining the machine, please shut off the main input power and wait 

for 5 minutes, until capacitors voltage already drop to safe voltage 36V!

 

 

Date 

Maintenance items 

Daily 

examinati

on 

Observe that the knobs and switches in the front and at the back of arc 

welding machine are flexible and put correctly in place.  If any knob has not 

been put correctly in place, please correct.  If you can't correct or fix the knob, 

please replace immediately;  

If any  

switch is not flexible or it can't be put correctly in place, please replace  

immediately.  Please get in touch with maintenance service department if there 

are no accessories. 

After turn-on power, watch/listen if the arc-welding  machine has shaking, 

whistle calling or peculiar smell.  If there is one of the above problems, find out 

the reason and clear it. If you can't find out the reason, please contact your local 

service repair station or distributor/agent .  

Observe that the display value of LED is intact. If the display number is  

not 

intact, please replace the damaged LED.  If it still doesn’t work, please maintain 

or replace the display PCB.  

Observe that the min/max values  

on  

LED agree with the set value. If there is 

any difference and it has affected the normal welding results, please adjust it. 

Check whether the fan is damaged and whether it is normal to rotate or 

control.  If the fan is damaged, please change immediately.  If the fan  does not 

rotate after the machine is overheated, observe if there is something blocking 

the blade.  If it is blocked, please clear the problem.  If the fan does not rotate 

after getting rid of the above problems, you can poke the blade by the rotation 

direction of fan. If the fan rotates normally, the start capacity should be 

replaced.  If not, change the fan.   

Observe whether the fast connector is loose or overheated. If  the arc- welding  

machine has the above problems, it should be fastened or changed.  

Observe whether the current output cable is damaged. If it is damaged, it 

should be insulated or changed.  

Monthly 

examinati

on 

Using the dry compressed air to clear the inside of arc welding machine. 

Especially for clearing up the dusts on radiator, main voltage transformer, 

inductors, IGBT modules, fast recover diodes, PCB’s, etc.  

Check the screws  

and bolts  

in the machine. If any is loose, please screw it 

tight.  If it is shaved, please replace. If it is rusty, please erase rust on all bolts to 

ensure it works well. 

Quarter- 

yearly 

examinati

on 

Check whether the actual current accords with the displaying value. If they did 

not accord, they should be regulated. The actual welding current value can be 

measured by and adjusted by plier-type ampere meter.  

Yearly 

examinati

on 

Measure the insulating impedance among the main circuit, PCB and case, if it 

below 1M

Ω

, insulation is thought to be damaged and need to change, and need 

to change or strengthen insulation.  

 

Содержание GRAND TIG 250 DC PULSE

Страница 1: ... GRAND TIG 250 DC PULSE IMPORTANT Read this OPERATOR MANUAL together with PRESCRIPTION AND COMPLIANCE MANUAL before to use this equipment In case of loss one of two parts contact immediately your dealer Allow the operator to consult this manual ...

Страница 2: ... MMA Welding 3 3 4 MMA Welding Fundamentals 3 3 5 MMA Welding troubleshooting 3 4 Installation Operation for TIG Welding 3 4 1 Set up installation for TIG Welding 3 4 2 Operation for TIG Welding 3 4 3 Remote current control 3 4 4 Tig Welding Techniques 3 4 5 Electrodes 3 4 6 TIG Welding troubleshooting 3 5 Remote control Configuration 3 5 1 Wireless remote control Configuration 3 5 2 Wire foot ped...

Страница 3: ...ply system Consideration should be given to shielding the supply cable of permanently installed arc welding equipment in metallic conduit or equivalent Shielding should be electrically continuous throughout its length The shielding should be connected to the welding power source so that good electrical contact is maintained between the conduit and the welding power source enclosure Maintenance of ...

Страница 4: ... to its voltage spikes Up Down Button Remote Control torch Roller wheel amps control on torch Integrated heavy duty industrial trolley and water cooler optional Wireless Remote Control optional Wire Wireless Foot Pedal optional 2 2 Technical Data Models Parameters GRAND TIG 250 DC PULSE Power Supply Voltage V 3 380V 400V 10 Frequency HZ 50 60 Rated input current A 20MMA 15 TIG Rated input power KW...

Страница 5: ... status and freezes quickly which can reduce the possibility to produce hot crack of the materials with thermal sensitivity 2 The workpiece gets little heat Arc energy is focused Be suitable for thin sheet and super thin sheet welding 3 Exactly control heat input and the size of the molten pool The depth of penetration is even Be suitable for welding by one side and forming by two sides and all po...

Страница 6: ...isplay value time indicator 12 Digital display value percentage indicator 13 RH voltage display 14 Welding output mode button 15 Hf TIG mode indicator 16 Lift TIG mode indicator 17 MMA mode indicator 18 2T trigger indicator 19 4T trigger indicator 20 Trigger control mode button 21 TIG parameter setting indicator 22 Parameter select adjust Knob 23 MMA arc force setting Indicator 24 MMA welding curr...

Страница 7: ... knob Value of the parameter selected will be shown on the digital multifunction display 18 TIG Parameter Setting Pre gas flow setting indicator 1 Controls the period shielding gas will flow for when the torch is triggered before the arc starts This purges the work area of atmospheric gas which could contaminate the weld before the weld starts Unit S and setting range 0 2S Start current setting in...

Страница 8: ...djustment the higher the minimum voltage that the power source will allow This effect will also cause the welding current to increase 0 is Arc Force off 10 is maximum Arc Force This is practically useful for electrode types that have a higher operating voltage requirement or joint types that require a short arc length such as out of position welds Water Air Cooling Selection Button 28 When using t...

Страница 9: ...n range 3 3 2 Operation for MMA Welding 1 According to the above method to install is correct turn the power switch so that the power switch is ON position then the power indicator light the fan comes on the device work properly 2 Set the welding mode button to MMA 3 Set the welding parameters as required using the parameters control knob following the instructions in the previous section 4 Place ...

Страница 10: ...ameter and by a series of letters and numbers The letters and numbers identify the metal alloy and the intended use of the electrode The flux on the electrode performs many diferent functions These include producing a protective gas around the weld area providing fluxing elements and deoxidizer creating a protective slag coating over the weld as it cools establishing arc characteristics adding all...

Страница 11: ... Use the correct welding technique or seek assistance for the correct technique 5 Lack of penetration Insufficient heat input Increase the amperage or choose a larger electrode Poor welding technique Use the correct welding technique or seek assistance for the correct technique Poor joint preparation Check the joint design and fit up make sure the material is not too thick Seek assistance for the ...

Страница 12: ...l or socket good contact and prevent oxidation 12 With a multi meter measure the input voltage is within the fluctuation range 13 The power ground is well grounded NOTE Secure the gas cylinder in an upright position by chaining them to a stationary support to prevent falling or tipping 3 4 2 Operation for TIG Welding 1 According to the above method to install is correct turn the power switch to th...

Страница 13: ...o ohm minimum connection to 10k ohm remote control potentiometer Not connected 6 Not connected The button of UP input 7 Not connected The button of DOWN input 8 Trigger Switch Input Trigger Switch Input 9 Trigger Switch Input Trigger Switch Input 10 Be shorted with 11 Not connected 11 Be shorted with 10 The button of UP DOWN input 12 Not connected Not connected 3 4 4 Tig Welding Techniques DC TIG ...

Страница 14: ...er wire into the weld pool with one hand while manipulating the welding torch in the other However some welds combining thin materials can be accomplished without filler metal like edge corner and butt joints This is known as Fusion welding where the edges of the metal pieces are melted together using only the heat and arc force generated by the TIG arc Once the arc is started the torch tungsten i...

Страница 15: ... Grinding longitudinally with the grain the electrons flow steadily and easily to the end of the tungsten tip The arc starts straight and remains narrow concentrated and stable Electrode Tip Flat The shape of the tungsten electrode tip is an important process variable in precision arc welding A good selection of tip flat size will balance the need for several advantages The bigger the flat the mor...

Страница 16: ...ated tungsten Touching tungsten into the weld pool Keep tungsten from contacting weld puddle Raise the torch so that the tungsten is off of the work piece 2 5mm Touching the filler wire to the tungsten Keep the filler wire from touching the tungsten during welding feed the filler wire into the leading edge of the weld pool in front of the tungsten Tungsten melting into the weld pool Check that cor...

Страница 17: ...ungsten is being used Too much current for the tungsten size so reduce the amps or change to a larger tungsten 7 Arc wanders during welding Poor gas flow Check and set the gas flow between 10 15 l min flow rate Incorrect arc length Lower torch so that the tungsten is off of the work piece 2 5mm Tungsten incorrect or in poor condition Check that correct type of tungsten is being used Remove 10mm fr...

Страница 18: ... back on again to start welding operation 5 If the operation is unsuccessful repeat steps 1 to 4 6 During operation the front panel control on the power supply is still functional but the remote control panel or foot pedal has higher priority level 7 When the remote control panel or foot pedal is idles for 10 seconds it will automatically go into sleep mode 8 Only front Panel Control is active whe...

Страница 19: ...iately If any switch is not flexible or it can t be put correctly in place please replace immediately Please get in touch with maintenance service department if there are no accessories After turn on power watch listen if thearc welding machine has shaking whistle calling or peculiar smell If there is one of the above problems find out the reason and clear it If you can t find out the reason pleas...

Страница 20: ...utput The welding cable damaged Repair or change it The earth cable connected unstably Check the earth cable The welding cable is too long Use an appropriate welding cable There is oil or dust on the workpiece Check and remove it The distance between tungsten electrode and workpiece is too long Reduce the distance about 3mm There is not spark on the HF igniting board The HF igniting board does not...

Страница 21: ... lamp thermal protection always on Welding machine E10 Phase loss Yellow lamp thermal protection always on E11 No water Yellow lamp lack water always on E13 Under voltage Yellow lamp thermal protection always on E14 Over voltage Yellow lamp thermal protection always on E15 Over current Yellow lamp thermal protection always on Switch E20 Button fault on operating panel when switch on the machine Ye...

Страница 22: ...4 4 Electrical schematic drawing ...

Страница 23: ...LOKERMANN Srl Via Produzione 16 18 37044 Cologna Veneta VR Italy Tel 39 0442 1722469 lokermann lokermann eu www lokermann eu ...

Отзывы: