Remote Control
Socket
Socket Pin
Function
1
Be shorted with 2
2
Be shorted with 1
3
20k ohm (maximum) connection to 20k ohm remote control potentiometer
4
Wiper arm connection to 20k ohm remote control potentiometer
5
Zero ohm (minimum) connection to 20k ohm remote control potentiometer
6
Not connected
7
Not connected
8
Trigger Switch Input
9
Trigger Switch Input
10
Not connected
11
Not connected
12
Not connected
3.6
Operation
environment
▲ Height above sea level ≤1000 M
▲ Operation temperature range -10
〜
+40°C
▲ Air relative humidity is below 90 %( 20°C)
▲ Preferable site the machine some angles above the floor level, the maximum
angle does not exceed 15
℃
.
▲ Protect the machine against heavy rain AND against direct sunshine.
▲ The content of dust, acid, corrosive gas in the surrounding air or substance
cannot exceed normal standard.
▲ Take care that there is sufficient ventilation during welding. There must be at
least 30cm free distance between the machine and wall.
3.7
Operation
Notices
▲ Read Section §1 carefully before starting to use this equipment.
▲ Connect the ground wire with the machine directly.
▲ Ensure that the input is single-phase: 50/60Hz, 110V/220V ±10%.
▲ Before operation, none concerned people should not be around the working
area and especially children. Do not watch the arc in unprotected eyes.
▲ Ensure good ventilation of the machine to improve Duty Cycle.
▲ Turn off the engine when the operation finished for energy consumption
efficiency.
▲ When power switch shuts off protectively because of failure. Don’t restart it until
problem is resolved. Otherwise, the range of problem will be extended.
▲ In case of problems, contact your local dealer if no authorized maintenance
staff is available.