![LOKERMANN GRAND MIG 400 PULSE Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/lokermann/grand-mig-400-pulse/grand-mig-400-pulse_user-manual_1938193028.webp)
0~t1: The machine starts to exhale (pre-gas time) When pressing the torch button.
t1~t2: The machine starts to wire feeding.
t2: The machine starts to weld and the current reach to the rated welding current.
t3~t4: When releasing the torch button, the controller automatically stops the welding
process, the current goes to zero, and the machine continue to exhale for some time
(post-gas time).
The pre-gas time and post-gas time couldn’t be adjusted under 2T cycles mode.
4T Cycles
The 4T cycles is provided for long welding, for the 4T cycles graphs of current see the
picture below.
27