5.1 
Troublesho-
oting 
Principle

There are extremely dangerous voltage and power levels present inside this unit. 
Do not attempt to diagnose or repair unless you have had training in power 
electronics measurement and troubleshooting techniques.

A. Power lamp and temperature lamp on

1. Air flow blocked, check for blocked air flow around the unit and correct c
    ondition.
2. Fan blocked, check and correct condition.
3. Unit is overheated, let unit cool down for at least 5 minutes. Make sure the unit 
    has not been  operated beyond Duty Cycle limit, refer to technology parameters 
    in Section 2.
4. Faulty components in unit, return for repair or have qualified technician repair per 
    Service Manual.

B. Torch fails to ignite the arc when torch switch is activated

1. System is in SET mode change to RUN mode.

2. Faulty torch parts, inspect torch parts and replace if necessary.
3. Gas pressure too high or too low, adjust to proper pressure.
4. Faulty components in unit, return for repair or have qualified technician repair per 
    Service Manual.

C. No cutting output; torch activated, power source on; gas flows; 
     fan operates

1. Torch not properly connected to power supply, check that torch leads are 
    properly connected to power supply.
2. Work cable not connected to work piece, or connection is poor, make sure that 
    work cable has a proper connection to a clean, dry area of the workpiece.
3. Faulty components in unit, return for repair or have qualified technician repair per 
    Service Manual.
4. Faulty Torch, return for repair or have qualified technician repair.

D. Low cutting output

1. Incorrect setting of CURRENT (A) control, check and adjust to proper setting.

2. Faulty components in unit, return for repair or have qualified technician repair.

E. Difficult starting

1. Worn torch parts (consumables), shut off input power. Remove and inspect torch 

   shield cup, tip and electrode. Replace electrode or tip if worn; replace shield cup
   if excessive spatter adheres to it.


Maintenance
&
Troublesho-
oting

Содержание GRAND CUT 60

Страница 1: ...ERATOR MANUAL together with PRESCRIPTION AND COMPLIANCE MANUAL before to use this equipment In case of loss one of two parts contact immediately your dealer Allow the operator to consult this manual U...

Страница 2: ...5 Volt Ampere Characteristic 3 INSTALLATION OPERATION 3 1 Layout for the front and rear panel 3 2 Installation Operation 3 3 Operation environment 3 4 Operation Notices 4 LKM CUT 60 TORCH 5 MAINTENAN...

Страница 3: ...and other control equipment d safety critical equipment for example guarding of industrial equipment e the health of the people around for example the use of pacemakers and hearing aids f equipment us...

Страница 4: ...th because of its size and position for example ship s hull or building steelwork a connection bonding the workpiece to earth may reduce emissions in some but not all instances Care should be taken to...

Страница 5: ...adequate to remove all fumes and gases The kinds of fumes and gases from the plasma arc depend on the kind of metal being used coatings on the metal and the di erent processes Use special equipment su...

Страница 6: ...ise levels to exceed safe limits You must protect your ears from loud noise to prevent permanent loss of hearing To protect your hearing from loud noise wear protective ear plugs and or ear mu s Prote...

Страница 7: ...n againt moisture Intelligent protection system protects plasma torch from damage Air ow manual activation switch to set test air pressure 2 Overview 2 1 Features 2 2 Technical Data Models Parameters...

Страница 8: ...rking Principle Rectify Inverter Medium frequency transformer Medium frequency rectify Hall device Current positive feedback control Three phase AC DC AC DC 380V 50Hz AC DC The letter X stands for Dut...

Страница 9: ...current I2 is as follows When I2 600A U2 80 0 4 I2 V When 165A I2 500A U2 130 0 1 I2 V When I2 500A U2 180 V 67 34 10 0 600 I2 A U2 V Working point Volt ampere characteristic The relation between the...

Страница 10: ...ap Bowl Denotes more detailed explanation of function to follow Further Controls Explained Alarm Indicator 5 Lights when over voltage over current or electrical overheating due to exceeding duty cycle...

Страница 11: ...ir Delivery FAD at 75psi pressure This normally means the compressor must be a belt drive model or if a direct drive it must have a motor power of 2 5HP or greater The air must be dry and free of oil...

Страница 12: ...n when install the shield cup and stop working 3 3 Operation environment Height above sea level 1000 M Operation temperature range 10 40 C Air relative humidity is below 90 20 C Preferable site the ma...

Страница 13: ...tion none concerned people should not be around the working area and especially children Do not watch the arc in unprotected eyes Ensure good ventilation of the machine to improve Duty Cycle Turn o th...

Страница 14: ...nd images are indicative and can be changed without notice SPARE PARTS 22535 22537 22536 22532 22534 40A 22543 60A 22526 22527 22548 60A 22529 40A 22546 50A 22540 22541 22542 22526 22527 22548 60A 225...

Страница 15: ...high or too low adjust to proper pressure 4 Faulty components in unit return for repair or have quali ed technician repair per Service Manual C No cutting output torch activated power source on gas o...

Страница 16: ...cycle speci cations 2 Gas pressure too low check source for at least 4bar 60psi adjust as needed It is need to open the machine cover 3 Torch consumables worn check torch shield cup tip starter elemen...

Страница 17: ...5 3 Electrical schematic drawing...

Страница 18: ...LOKERMANN Srl Via Produzione 16 18 37044 Cologna Veneta VR Italy Tel 39 0442 1722469 lokermann lokermann eu www lokermann eu...

Отзывы: