LOKERMANN GRAND CUT 60 Скачать руководство пользователя страница 14

Lokermann S.r

.l.

V

ia Produzione 16/18

37044- Cologna V

eneta (VR)- Italy

Phone:+39 0442 1722469

W

ebsite: www

.lokermann.eu

IEC 60974-7

Reference numbers are for your convenience only

.    Data and images are indicative and can be changed without notice.

SP

ARE P

ARTS

22535

22537

22536

22532

22534 (40A)

22543 (60A)

22526

22527

22548

 

(60A)

22529 

(40A)

22546 

(50A)

22540*

22541*

22542*

22526*

22527*

22548* 

(60A)

22529 

(40A)

22546 

(50A)

22553 

22554 

22527

22540

22541

22544

22526

22527

SP

ACER

DRAG

EXTENDED

GOUGING***

22540

22541

22557

22556

22524

Torch

Torch spares

Further Controls Explained
Alarm Indicator (5)

Lights when over voltage, over current or electrical overheating (due to 

exceeding duty cycle) is detected and protection is activated. When protection is 

activated, welding output will be disabled until the safety system senses the 

overload has reduced sufficiently and indicator lamp goes out. May also trigger 

if machine experiences an  internal power circuit failure.

Torch System Error Indicator (6

 

)

 

Lights when issue with torch system or air supply detected and cutting output is 

disabled as a result. Flashing light means that torch shield cap is not installed. 

Continuous light means likely damaged or missing torch consumables or insufficient 

air pressure supply to the torch.

 

4

LKM Cut 60
Torch spares
parts

22547

Содержание GRAND CUT 60

Страница 1: ...ERATOR MANUAL together with PRESCRIPTION AND COMPLIANCE MANUAL before to use this equipment In case of loss one of two parts contact immediately your dealer Allow the operator to consult this manual U...

Страница 2: ...5 Volt Ampere Characteristic 3 INSTALLATION OPERATION 3 1 Layout for the front and rear panel 3 2 Installation Operation 3 3 Operation environment 3 4 Operation Notices 4 LKM CUT 60 TORCH 5 MAINTENAN...

Страница 3: ...and other control equipment d safety critical equipment for example guarding of industrial equipment e the health of the people around for example the use of pacemakers and hearing aids f equipment us...

Страница 4: ...th because of its size and position for example ship s hull or building steelwork a connection bonding the workpiece to earth may reduce emissions in some but not all instances Care should be taken to...

Страница 5: ...adequate to remove all fumes and gases The kinds of fumes and gases from the plasma arc depend on the kind of metal being used coatings on the metal and the di erent processes Use special equipment su...

Страница 6: ...ise levels to exceed safe limits You must protect your ears from loud noise to prevent permanent loss of hearing To protect your hearing from loud noise wear protective ear plugs and or ear mu s Prote...

Страница 7: ...n againt moisture Intelligent protection system protects plasma torch from damage Air ow manual activation switch to set test air pressure 2 Overview 2 1 Features 2 2 Technical Data Models Parameters...

Страница 8: ...rking Principle Rectify Inverter Medium frequency transformer Medium frequency rectify Hall device Current positive feedback control Three phase AC DC AC DC 380V 50Hz AC DC The letter X stands for Dut...

Страница 9: ...current I2 is as follows When I2 600A U2 80 0 4 I2 V When 165A I2 500A U2 130 0 1 I2 V When I2 500A U2 180 V 67 34 10 0 600 I2 A U2 V Working point Volt ampere characteristic The relation between the...

Страница 10: ...ap Bowl Denotes more detailed explanation of function to follow Further Controls Explained Alarm Indicator 5 Lights when over voltage over current or electrical overheating due to exceeding duty cycle...

Страница 11: ...ir Delivery FAD at 75psi pressure This normally means the compressor must be a belt drive model or if a direct drive it must have a motor power of 2 5HP or greater The air must be dry and free of oil...

Страница 12: ...n when install the shield cup and stop working 3 3 Operation environment Height above sea level 1000 M Operation temperature range 10 40 C Air relative humidity is below 90 20 C Preferable site the ma...

Страница 13: ...tion none concerned people should not be around the working area and especially children Do not watch the arc in unprotected eyes Ensure good ventilation of the machine to improve Duty Cycle Turn o th...

Страница 14: ...nd images are indicative and can be changed without notice SPARE PARTS 22535 22537 22536 22532 22534 40A 22543 60A 22526 22527 22548 60A 22529 40A 22546 50A 22540 22541 22542 22526 22527 22548 60A 225...

Страница 15: ...high or too low adjust to proper pressure 4 Faulty components in unit return for repair or have quali ed technician repair per Service Manual C No cutting output torch activated power source on gas o...

Страница 16: ...cycle speci cations 2 Gas pressure too low check source for at least 4bar 60psi adjust as needed It is need to open the machine cover 3 Torch consumables worn check torch shield cup tip starter elemen...

Страница 17: ...5 3 Electrical schematic drawing...