background image

Basic safety guidelines

 

 

2.1 

Following the guidelines

  

Please read this user guide very carefully and follow the procedures saved in this 
document.  

 
2.2 

Staff 

Handling and protection service should not be made

 

by not properly prepared staff 

without authorization. Scale should be handled by trained staff. 

 
2.3 

Basic safety guidelines  

- Make sure that device is in good technical condition. 
- Do not use devise for transporting people or as a scooter. 
- Avoid contact with dangerous elements of scale (load, fork and lift mechanism) 
- During work choosing arm should be placed in neutral position. 
- Please keep safe distances from dangerous slopes edges, holes, loading ramp and 
platforms 
- Please keep safe driving on unstable loading ramps and platforms. Collapse from 
loading ramp or platform can cause serious injurious or even death. 
- Any transported goods should be protected. 
- Never overstep device capacity shown on the identification label. 
- Ride up directly using both forks towards  
- Avoid driving on slopes and holes. Appling safety handbrake is possible only through 
quick lower the weight. 
- When driving on slopes and 

holes, 

weight always should be faced slopes. It is not 

aloud driving slantwise or turns round. 
- Please follow capacity of loading ramps and lofts. 
- During longer route the goods should be pulled, not  pushed (it provides better visibility 
and improves driving device!). 
- Observe the height of goods in reference to height of doorways. 
- Device should be placed on flat surface keeping the fork with thrill in upright position. 

4

Содержание WSP 2200

Страница 1: ...User Guide Handpallet weighter WSP 2200...

Страница 2: ......

Страница 3: ...king under extreme conditions Through load capacity we understand equally placed weight not point overloading The scale cannot be used for any dynamic weighting Any sudden change on the scale example...

Страница 4: ...nd platforms Please keep safe driving on unstable loading ramps and platforms Collapse from loading ramp or platform can cause serious injurious or even death Any transported goods should be protected...

Страница 5: ...he pallet The loading and unloading device from the truck should be preceded using correct equipment After the unloading remove safety labels unpack and take off the device from the pallet Delivered s...

Страница 6: ...or vibrations Do not expose for long effect of sun Do not use it in places where corrosion gases can be found Free of dust environment Temperature environment from 10 C to 40 C Average moistness of ai...

Страница 7: ...dedicated dealer 5 2 Operating the handpallet KPZ scales are endowed with easy operating mechanism to weightlifting neutrality and to lower the work lift Lower the work lift Choosing arm pull up and...

Страница 8: ...imum capacity cannot be overloaded Sudden strong impingements can damage load cells of the scale Avoiding strong impingements extend longevity of load cells To reassure long lasting weighting values i...

Страница 9: ...9...

Страница 10: ...er should be checked before using for any damages If the charging device is damaged by accident or if any other defect exists please check the output If the output is affected in any way immediately o...

Страница 11: ...storaged in dry and free of dust environment From time to time accumulator should be charge because its is discharging while storage 7 3 Carrying Routine technical inspection should be carried for its...

Страница 12: ...12...

Страница 13: ...User Guide 8 0 Indicator 8 1 Frontview of Indicator 13...

Страница 14: ...cation GROSS Gross weight indication M Accumulation mode indication PT Pretare indication 1 Range indication for multirange kg kg unit Pcs peace unit counting mode Set point indication HI High limit v...

Страница 15: ...izing Modus selection Function Switching between net and gross weight net mode switching units Switch between weight unit weight piece counting mode Tare 1 Backlight 2 Switch on zero setting 3 Gravita...

Страница 16: ...GROSS gross appears Pretare Press the key whom there is no weight on the scale Enter the weight using the cursor function and confirm with the Enter key 0 9 9 0 Function Switching between the operatin...

Страница 17: ...9 General Functions Weighing Modus Reference piece count function 9 1 Target weight function 9 2 Addition function 9 3 Hold function 9 4 kg 1 0 6 1 0 Pcs 17...

Страница 18: ...election of reference pcs 1 Place the reference quantity 2 Put on pieces 3 Display of total weight and weight 1 0 1 0 1 0 Change over after 1sec Piece Total Weight 1 Pcs 1 1 0 Pcs kg 1 kg 1 after 1sec...

Страница 19: ...tone No signal tone Signal inside OK value Signal inside HI LO value 1 Enter the desired values 0 9 Hi 3 000kg Lo 1 000kg 1 Apply your settings start and function HI OK LO LED Kg 10d Target weight fun...

Страница 20: ...displayed for 0 5 seconds A new addition is possible after the weight returns to zero The Addition is printed in the or printformat The smallest possible addition weight is 10 division steps 2 Subtot...

Страница 21: ...d Function 1 Hold function is disabled after the load is taken off and the display 0kg displays Hold function is disabled when weight is above below the selected tolerance of the division d Calculatio...

Страница 22: ...ttery voltage For 1 sec 1sec Volt Autom return to the weighing mode after 3 seconds kg 1 0 6 0 9 9 0 Autom start Error Enter value 1 sec Press key LCD backlight Zeroindication 0 9d Gravitation value L...

Страница 23: ...while switching on the scale example Scale is incorrect sets up load receptor is not loaded problem with turning on load cell is damaged E4 Zero value is not stable while switching on the scale exampl...

Страница 24: ...S1022 WSP 2200_en 310117...

Отзывы: