6.0 Long live the Rotator
6.2 Oil change
Draining the oil:
1. Bring the unloaded forks down to the lowest position.
2. Most of the oil can be drained by loosening the hydraulic hose union in the
bottom of the cylinder. Activate the hydraulic pump by pressure on the switch.
The oil will run out.
3. Take off the side plates.
4.
Take off the cables of the battery and push the battery box to the right side.
5 The remaining oil can be drained from the oil tank by taking off the oil tank.
6. Place the oil tank and the hydraulic hose again.
7. Oil is filled in by removing the angular hose nipple from the tank
.
8. Oil quantity:
The oil level is measured from the upper edge of the tank and downwards
Oil quantity:
SELFR 1001/920-1600 & SELFSR 1001/890 - 1570 approx. 3 litre 40 mm
SELFR 1001/1910-2450 & SELFSR 1001/1880-2420 approx.
3,5 litre 32 mm
SELFR 1001/2850 & SELFSR 1001/2820
approx.
4 litre 25 mm
SELFR 1001/3300 & SELFSR 1001/3270
approx.
4,5 litre Metal tank
half full
9. Refit the angular hose nipple and bleed the system (see 6.5).