5.0 There must be a current supply...
5.1 Fuses - replacement
There are five fuses in the electrical circuit.
100 Amp
fuse in the main supply
from battery
10 Amp
fuse in the control
current circuit
20 Amp
fuse for built-in charger
40 Amp
fuse for Rotator
100 Amp
fuse for the hydraulic pump
Replacement:
The old fuse is to be removed and replaced by a new one of the same size.
Find out why the fuses blow!
Many operational disturbances are caused by bad
connections in the electrical circuit. Make sure that the
connections are in order.
Check connections regularly for damage at insulating caps or
bad connections at plugs etc. Verdigris must be removed from
cable plugs. Keep all screw/nut connections tight.