7
* All images are for indication only; please refer to your individual unit for actual item.
Minimum cable
H05VV- F4 mm
2
8061424
Grounding lead must be connected
to screw with symbol.
Making an Electrical Connection
An approved suitable cable must be connected from the Consumer Unit (main fuse box)and be protected by
its own 30amp fuse or Micro Circuit Breaker (MCB).
The electrician must provide a fused double-pole isolation switch, which disconnects both the line (live) and
neutral conductors, with a contact separation of at least 3 mm incorporated into the fixed wiring. The fused
switch should be fitted to the kitchen wall, and must be placed in an easy accessible position in accordance
with IEE regulations. Connect the fused switch to a junction box which should be fitted on the wall. The ovens
power supply cable can then be connected. Connect one end to the junction box and connect the other end
to the ovens power connection box which is located at the back of the oven. Remove the cover of the power
connection box and install the cable, in accordance with the connection diagram. The power supply cable must
be positioned away from direct heat sources. It should not be subjected to a temperature rise of more than
50°C above room temperature.
Terminal Box Connections
For this oven, the cable type must be a minimum of H05VV-F
(PVC insulated and sheathed) 3 cores x 4mm
2
and the connection
should be made as detailed below.
This appliance must be earthed
Green / Yellow (Earth) to the PE ( ) terminal
Brown (Live) wire to the terminal marked L
Blue (Neutral) wire to the terminal marked N
Ensure the cable exits through the cable grip
clamping on the outer sheath of the cable
and fix in place by tightening the fixing screw.
Max length of cable to be used is 2m.
Ensure all screws are adequately tightened.
Do not over tighten as you may risk damaging
the screw threads.
Minimum cable
H05VV- F4 mm
2
8061424
LBUDOX16_IB.indd 7
09/06/2016 14:16