60
ENG
specific clamp as per current installation stan-
dards. The bottle must be fitted with a pressure
reducer as per current installation standards.
Cookers with bottle cupboard IF INSTALLATION
STANDARDS PERMIT.
These cookers are designed prepared for use
with bottle of liquid gas (size Ø 270 mm, height
600 mm). They are fitted with two attachments
for the gas connection: one inside the cupboard
and one on the back hand side.
The bottle cupboard attachment is sealed with
a cap and a gasket, while the other end is open.
If the bottle cupboard attachment is used, the
cap must be replaced with the pipe holder must
be connected with a flexible pipe, which must
follow the route shown in the adjacent diagrams
and/or on the adhesive plate fitted inside the
bottle cupboard door.
After connection, ensure that there are no gas
leaks by using a specific instrument or soapy
water.
3.6 Connection to the
electricity supply
The flexible mains lead is supplied connected
to a BS 1363 fused plug fitted with a fuse of 13
amp capacity. If you need to replace the plug for
any reason, it should be carried out as outlined
below.
WARNING: THIS APPLIANCE MUST BE
EARTHED.
The wired in the mains lead are coloured in
accordance with the following code:
Green & Yellow = Earth – Blue= Neutral –
Brown= Live
As the colours of the wires in the mains lead
of the appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:
1.
The wire which is coloured Green
& Yellow must be connected to the terminal
marked E (Earth) or coloured Green.
2.
The wire which is coloured Blue
must be connected to the terminal marked N
(Neutral) or coloured Black.
3.
The wire which is coloured Brown
must be connected to the terminal marked L
(Live) or coloured Red.
The plug and socket must be accessible after
installation. Should the mains lead ever need
replacing it is recommended that this operation
is carried out by a qualified electrician who
will replace it with a lead of the same size and
temperature rating.
If a fixed instrument has not any cable nor pin,
or any other device which assures the worknet
disconnection, with a distance of opening of the
contacts that allows the complete disconnection
in the conditions of overvoltage category III,
the instructions have to inform that such
disconnection devices have to be provided for
by the supply mains in conformity with the
installation rules.
Terminal connection diagram with cable pre-