55
ENG
User Manual: Installation Of The Cooker
WARNING:
This appliance shall be installed in accordance with the
regulations in force and only in a well ventilated space.
Read the instructions before installing or using the appliance.
In the UK the regulations and standards are as follows:
In your own interest and that of safety, it is law that
all gas appliances be installed by competent persons.
CORGI registered installers undertake to work to safe and
satisfactory standards. Failure to install the appliance
correctly could invalidate any warranty of liability claims and
lead to prosecution.
3. INSTALLATION OF THE COOKER
The cooker must be installed in accordance
with all relevant British Standards / Codes of
Practice, in particular BS 5440 Part 2 2000 and:
• For Natural Gas – BS6172: 1990 and
BS6891: 1988
• For LP Gas – BS5482 Part 1 (when
the installation is in a permanent
dwelling), Part 2, (when the installation
is in a caravan or other non permanent
dwelling), or Part 3 (when installing is in
a boat).
• The Gas Safety (Installing and Use)
regulations 1994 (as amended).
• The relevant Building /IEE regulations.
• The cooker may be installed in a
kitchen / kitchen diner but NOT in a room
containing a bath or shower.
• If the appliance is for use on LPG it
must not be fitted below ground level, i.e.
in a basement.
Fig. 1
3.1 Ventilation
The room containing this cooker should have
an air supply in accordance with BS 5440: Part
2: 1989
• All rooms require an openable
window, or equivalent and some rooms
will require a permanent vent a well.
• For room volumes up to 5 m3 an air
vent of 100 cm2 is required.
• For room volumes between 5 m3 and
10 m3 an air vent of 50 cm2 is required.
• If the room is greater than 5 m3 and
Содержание PR126SMFE+MF/2Ci