12
5 Dispensing
5.2 Adjusting the Dispensing Quantity
The dispensed quantity is adjusted by setting the size of the dispensing chamber in the
dispenser.
•
Adjust the required amount of adhesive
by turning the stroke adjustment knob 7
clockwise or counter-clockwise to
decrease or increase the effective size
of the chamber.
•
Start dispensing to check the dispensed
amount.
•
Go further with this procedure till the
amount is reached.
•
Protect the adjustment with the
lock nut 6.
5.3 Shutdown
For short idle periods, 24 hours or less, the system can be left idle without any special
preparations.
It is necessary to change the dispensing needle against the luer-lock tip cap to prevent
curing of the adhesive.
For periods 1 week or longer remove the adhesive from the reservoir and purge the
system with fresh acetone to clear feedline, dispenser and fittings of adhesive.
5.4 Returning to Operation
•
Insert product bottle into the reservoir.
•
Possibly replace the Luer-Lock tip cap with a new dispensing needle.
•
Purge the Dispenser until product runs out bubble free out of it, see section 5.1.
?
Check the adjustment of the dispensing quantity according to of the operating manual of
the used controller.
+
-