3 Operation
3.8.5
Enter calibration factor
The capacity of pump B is calibrated to ensure accurate control and consistency of
Part A and Part B mixing ratios.
The capacity of pump A is the reference value (100%). For determination of the
calibration factor proceed as described in Section 3.4.
Enter calibration factor:
• With the dispensing station in ready state, push
*
button twice - display indicates
Enter password
.
• Enter password, see Section 3.8.1.
• Push OK button three times - display indicates
Calibration factor
.
• Use arrow keys to enter desired value.
Arrow key
assignment / setting range:
left
: -10;
right
: +10;
up
: +1;
down
: -1; setting range: 70 – 140.
• Push
OK
button to save the setting – display indicates "
next menu item
".
Push
ESC key to leave the service menu – display indicates
Operation
.
3.8.6
Select User Interface language
Messages can be displayed in German or in English.
Interface language setup:
• With the dispensing station in ready state, push
*
button twice - display indicates
Enter password
.
• Enter password, see Section 3.8.1.
• Push
OK
button 4 times - display indicates
Language selection
or
The following languages can be
adjusted:
– Deutsch
– French
– Italian
– Portuguese
• Use arrow keys to enter desired value.
Arrow key
assignment / setting range:
left
: German;
right
: English
• Push
OK
button to save the setting – display indicates "
next menu item
".
Push
ESC key to leave the service menu – display indicates
Operation
.
Language
english
OK/ESC
Adjustment
105
%
OK/ESC