Notice:
If a radiometer is not available, it is recommended that Loctite
®
Service be contacted at
1-800-LOCTITE (1-800-562-8483) to insure optimum performance when installing a
new multi-pole light guide.
7.
Care and Maintenance
Notice:
It is recommended that the UV output from the lamp be monitored regularly using a
Loctite
®
7020 UV Spot Radiometer P/N: 1406024. If a radiometer is not used to
monitor the lamp, it is recommended that the lamp be replaced when the LCD display
indicates 1,000 hours of operating time has elapsed. It is normal for the lamp output to
slowly decline over operating time, however, the effective life of the lamp will decrease
significantly faster if it is turned on and off frequently.
Caution!
It is recommended that the end of the light guide be positioned no closer than ½ inch
from the Loctite® product being cured. The heat transmitted by the lamp can adversely
affect the properties of the cured product or possibly cause damaged to the part surface.
Notice:
Vapors from some products may gradually accumulate on the end of the light guide,
reducing the UV output. It should be inspected regularly and cleaned as necessary using
isopropyl alcohol and a soft, clean cloth.
Caution!
Avoid placing sharp bends in the light guide. This reduces the UV output and may
permanently damage the light guide. If the light guide is mounted on a fixture, secure it
by the metal exit fitting and not the flexible plastic section.
Caution!
Be sure to remove the plastic end caps before attempting to use the light guide.
Notice:
The intake and exhaust fan filter elements should be replaced as needed to
insure proper cooling of the power supply and UV lamp assembly. They should be
inspected routinely.
7.1
Replacing the Lamp
Caution!
Do not touch the inside surface of the lamp reflector or the bulb . Contaminants
from hands will create
“
hot spots
”
and cause the module to fail prematurely. If either one is
accidentally touched, carefully wipe clean using soft cloth and isopropyl alcohol.
1. Switch the power off and unplug the unit.
2. Allow several minutes for the installed lamp to cool.
Содержание CL15 UV
Страница 22: ......