Care and Maintenance
To insure maximum light output of the system, all components must be clean. Dirt on the lamp
and reflector will reduce the ultraviolet intensity by absorbing ultraviolet energy and turning it into
unwanted infrared energy. Lamps and reflectors should be inspected and cleaned at least once
each month. If conditions are extremely bad, cleaning may be required more often.
Lamps should be handled only when cool and with clean cotton gloves;
do not touch the lamp
with bare hands. Oils on your hands will etch the quartz glass, and create hot spots on the
lamp, and can reduce lamp life.
5.1
Cleaning Lamp and Reflector
The UV lamp and reflector may be cleaned using a clean soft lint free cloth dampened with
isopropyl alcohol. After cleaning, wipe dry with a soft clean cotton cloth.
5.2
Removing the Lamp
1. If unit has been in service, allow at least 15 minutes for cooling before removing lamp.
2. Unplug line cord.
3. Unplug 8 pin connector from the rear of the lamp unit.
4. Remove grills from both sides of the lamp unit. Each grill has (4) screws - (2) on the front and
(2) on the side.
5. Remove lamp bracket clamp screw and nut.
6. Wearing clean cotton gloves, remove the UV lamp.
7. Reverse the procedure to replace the lamp.
5.3
Removing the Reflector
As a result of excess heat or other misuse, the reflectors may blacken or warp. If the unit has
been in service, allow at least 15 minutes for cooling before removing reflectors.
1. Remove lamp unit rear panel by removing the four screws on the side of the case.
2. Remove lamp bracket assembly.
3. Remove reflector support screws from the side of the chassis.
4. Remove the reflectors.
5. Replace the reflectors and reassemble in reverse order.